Chromatographic properties of reversed-phase stationary phases under pressure- and electro-driven conditions

被引:16
作者
Jiskra, J
Cramers, CA
Byelik, M
Claessens, HA
机构
[1] Eindhoven Univ Technol, Dept Instrument Anal, NL-5600 MB Eindhoven, Netherlands
[2] Ukrainian Acad Sci, Inst Bioorgan Chem & Petrochem, UA-253660 Kiev 94, Ukraine
关键词
stationary phases; LC; electrochromatography; hydrophobicity; silanols; hydrophobic selectivity; reversed-phase materials;
D O I
10.1016/S0021-9673(99)00933-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Seven different reversed-phase (RP) stationary phases were examined under high-performance liquid chromatographic (pressure-driven, HPLC), and capillary electrochromatographic (electro-driven, CEC) conditions. Characterization of the stationary phases was performed following well-established test procedures providing a number of distinct column descriptors: hydrophobicity, hydrophobic selectivity and silanol activity. These parameters were used to describe the behavior of the RP-columns under both HPLC and CEC conditions. It is shown that chromatographic characteristics of porous RP-phases greatly depend on the mode of operation. By contrast, column descriptors of a non-porous viz. solid RP-phase material hardly differed for HPLC and CEC conditions. (C) 1999 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:121 / 135
页数:15
相关论文
共 51 条
[11]   Capillary electrochromatography - A high-efficiency micro-separation technique [J].
Dittmann, MM ;
Rozing, GP .
JOURNAL OF CHROMATOGRAPHY A, 1996, 744 (1-2) :63-74
[12]  
Dittmann MM, 1997, J MICROCOLUMN SEP, V9, P399, DOI 10.1002/(SICI)1520-667X(1997)9:5<399::AID-MCS6>3.0.CO
[13]  
2-X
[14]   Retention of neutral solutes in capillary electrochromatography [J].
Djordjevic, NM ;
Fowler, PWJ ;
Houdiere, F ;
Lerch, G .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (14) :2219-2232
[15]   THE MOLECULAR MECHANISM OF RETENTION IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
DORSEY, JG ;
DILL, KA .
CHEMICAL REVIEWS, 1989, 89 (02) :331-346
[16]   Selectivity tuning in pressurized-flow electrochromatography [J].
Eimer, T ;
Unger, KK ;
vanderGreef, J .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (09) :463-468
[17]   Capillary electrochromatography in the pharmaceutical industry. Practical reality or fantasy? [J].
Euerby, MR ;
Johnson, CM ;
Bartle, KD ;
Myers, P ;
Roulin, SCP .
ANALYTICAL COMMUNICATIONS, 1996, 33 (11) :403-405
[18]  
EUERBY MR, 1998, LC GC EUR, V11, P39
[19]   STATIONARY PHASES FOR REVERSED-PHASE LIQUID-CHROMATOGRAPHY - COATING OF SILICA BY POLYMERS OF VARIOUS POLARITIES [J].
FIGGE, H ;
DEEGE, A ;
KOHLER, J ;
SCHOMBURG, G .
JOURNAL OF CHROMATOGRAPHY, 1986, 351 (03) :393-408
[20]   THE CALCULATION OF RETENTION AND SELECTIVITY IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY .2. METHANOL-WATER ELUENTS [J].
GALUSHKO, SV .
CHROMATOGRAPHIA, 1993, 36 :39-42