Monolithically integrated dye-doped PDMS long-pass filters for disposable on-chip fluorescence detection

被引:118
作者
Hofmann, Oliver
Wang, Xuhua
Cornwell, Alastair
Beecher, Stephen
Raja, Amal
Bradley, Donal D. C.
deMello, Andrew J.
deMello, John C.
机构
[1] Mol Vis Ltd, London EC4A 1JP, England
[2] Univ London Imperial Coll Sci & Technol, Dept Phys, London SW7 2AZ, England
[3] Univ London Imperial Coll Sci & Technol, Dept Chem, London SW7 2AZ, England
关键词
D O I
10.1039/b603678c
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report the fabrication of high quality monolithically integrated optical long-pass filters, for use in disposable diagnostic microchips. The filters were prepared by incorporating dye molecules directly into the microfluidic chip substrate, thereby providing a fully integrated solution that removes the usual need for discrete optical filters. In brief, lysochrome dyes were added to a poly(dimethylsiloxane) (PDMS) monomer prior to moulding of the microchip from a structured SU-8 master. Optimum results were obtained using 1 mm layers of PDMS doped with 1200 mg mL(-1) Sudan II, which resulted in less than 0.01% transmittance below 500 nm (OD 4), > 80% above 570 nm, and negligible autofluorescence. These spectral characteristics compare favourably with commercially available Schott-glass long-pass filters, indicating that high quality optical filters can be straightforwardly integrated into the form of PDMS microfluidic chips. The filters were found to be robust in use, showing only slight degradation after extended illumination and negligible dye leaching after prolonged exposure to aqueous solutions. The provision of low cost high quality integrated filters represents a key step towards the development of high-sensitivity disposable microfluidic devices for point-of-care diagnostics.
引用
收藏
页码:981 / 987
页数:7
相关论文
共 29 条
[1]   Microfluidic integration on detector arrays for absorption and fluorescence micro-spectrometers [J].
Adams, ML ;
Enzelberger, M ;
Quake, S ;
Scherer, A .
SENSORS AND ACTUATORS A-PHYSICAL, 2003, 104 (01) :25-31
[2]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[3]   Mesoscale self-assembly of hexagonal plates using lateral capillary forces: Synthesis using the "capillary bond" [J].
Bowden, N ;
Choi, IS ;
Grzybowski, BA ;
Whitesides, GM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1999, 121 (23) :5373-5391
[4]   An integrated nanoliter DNA analysis device [J].
Burns, MA ;
Johnson, BN ;
Brahmasandra, SN ;
Handique, K ;
Webster, JR ;
Krishnan, M ;
Sammarco, TS ;
Man, PM ;
Jones, D ;
Heldsinger, D ;
Mastrangelo, CH ;
Burke, DT .
SCIENCE, 1998, 282 (5388) :484-487
[5]   An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications [J].
Chabinyc, ML ;
Chiu, DT ;
McDonald, JC ;
Stroock, AD ;
Christian, JF ;
Karger, AM ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2001, 73 (18) :4491-4498
[6]   Heterogeneous integration of CdS filters with GaN LEDs for fluorescence detection microsystems [J].
Chediak, JA ;
Luo, ZS ;
Seo, JG ;
Cheung, N ;
Lee, LP ;
Sands, TD .
SENSORS AND ACTUATORS A-PHYSICAL, 2004, 111 (01) :1-7
[7]   Seeing single molecules [J].
de Mello, AJ .
LAB ON A CHIP, 2003, 3 (02) :29N-34N
[8]   An improved experimental determination of external photoluminescence quantum efficiency [J].
deMello, JC ;
Wittmann, HF ;
Friend, RH .
ADVANCED MATERIALS, 1997, 9 (03) :230-&
[9]   Thin-film polymer light emitting diodes as integrated excitation sources for microscale capillary electrophoresis [J].
Edel, JB ;
Beard, NP ;
Hofmann, O ;
DeMello, JC ;
Bradley, DDC ;
deMello, AJ .
LAB ON A CHIP, 2004, 4 (02) :136-140
[10]   Thin-film organic photodiodes as integrated detectors for microscale chemiluminescence assays [J].
Hofmann, O ;
Miller, P ;
Sullivan, P ;
Jones, TS ;
deMello, JC ;
Bradley, DDC ;
deMello, AJ .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 106 (02) :878-884