Patient and staff dosimetry in vertebroplasty

被引:82
作者
Fitousi, Niki T.
Efstathopoulos, Efstathios P.
Delis, Harry B.
Kottou, Sofia
Kelekis, Alexis D.
Panayiotakis, George S. [1 ]
机构
[1] Univ Patras, Sch Med, Dept Med Phys, Patras 26500, Greece
[2] Univ Athens, Sch Med, Dept Med Phys, Athens, Greece
[3] Univ Athens, Sch Med, Dept Radiol 2, Athens, Greece
关键词
vertebroplasty; dosimetry; radiation protection;
D O I
10.1097/01.brs.0000244586.02151.18
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Eleven vertebroplasty operations were studied in terms of radiation dose. Objective. Doses to patients and staff associated with vertebroplasty were measured. Occupational doses were compared with the annual dose limits, and the effectiveness of the used radiation protection means was estimated. Patient dose was estimated by means of both surface and effective dose, and the radiation-induced risk was evaluated. Summary of Background Data. Vertebroplasty is a recent minimally invasive technique for the restoration of vertebral body fractures. It involves fluoroscopic exposure, and so, it demands dose measurements for both patient and staff exposed to radiation. Methods. Thermoluminescent dosimeters (TLDs) were placed on the medical personnel and the effective dose was derived. Slow films were placed to patients' skin to measure entrance surface dose. Furthermore, a Rando phantom loaded with TLDs was irradiated under conditions simulating vertebroplasty, in order to estimate effective dose to the patient. Results. Mean fluoroscopy time was 27.7 minutes. Patient's mean skin dose was 688 mGy, while effective dose was calculated to be 34.45 mGy. It was estimated that the primary operator can perform about 150 vertebroplasty operations annually without exceeding the annual dose constraints, whereas occupational dose can be reduced by 76% using mobile shielding. Conclusions. Measures have to be taken to reduce patient's skin dose, which, in extreme cases, may be close to deterministic effects threshold. The highest dose rates, recorded during the procedure, were found for primary operator's hands and chest when no shielding was used.
引用
收藏
页码:E884 / E889
页数:6
相关论文
共 18 条
[1]
[Anonymous], 1991, ANN ICRP, V60
[2]
Fluoroscopic radiation exposure of the kyphoplasty patient [J].
Boszczyk, BM ;
Bierschneider, M ;
Panzer, S ;
Panzer, W ;
Harstall, R ;
Schmid, K ;
Jaksche, H .
EUROPEAN SPINE JOURNAL, 2006, 15 (03) :347-355
[3]
ESTIMATION OF EFFECTIVE DOSE EQUIVALENT TO STAFF IN DIAGNOSTIC-RADIOLOGY [J].
FAULKNER, K ;
HARRISON, RM .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (01) :83-91
[4]
FAULKNER K, 2000, 10 INT C INT RAD PRO
[5]
New technologies in spine - Kyphoplasty and vertebrosplasty for the treatment of painful osteoporotic compression fractures [J].
Garfin, SR ;
Yuan, HA ;
Reiley, MA .
SPINE, 2001, 26 (14) :1511-1515
[6]
Practical aspects for the evaluation of skin doses in interventional cardiology using a new slow film [J].
Guibelalde, E ;
Vano, E ;
Gonzalez, L ;
Prieto, C ;
Fernandez, JM ;
Ten, JI .
BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (905) :332-336
[7]
HART D, 1994, NRPBR262
[8]
Radiation dose reduction to medical staff during vertebroplasty - A review of techniques and methods to mitigate occupational dose [J].
Kruger, R ;
Faciszewski, T .
SPINE, 2003, 28 (14) :1608-1613
[9]
Radiation dose in vertebroplasty [J].
Mehdizade, A ;
Lovblad, KO ;
Wilhelm, KE ;
Somon, T ;
Wetzel, SG ;
Kelekis, AD ;
Yilmaz, H ;
Abdo, G ;
Martin, JB ;
Viera, JM ;
Rüfenacht, DA .
NEURORADIOLOGY, 2004, 46 (03) :243-245
[10]
Radiation doses in interventional radiology procedures: The RAD-IR Study - Part I: Overall measures of dose [J].
Miller, DL ;
Balter, S ;
Cole, PE ;
Lu, HT ;
Schueler, BA ;
Geisinger, M ;
Berenstein, A ;
Albert, R ;
Georgia, JD ;
Noonan, PT ;
Cardella, JF ;
George, JS ;
Russell, EJ ;
Malisch, TW ;
Vogelzang, RL ;
Miller, GL ;
Anderson, J .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (06) :711-727