Force in the Achilles Tendon During Walking With Ankle Foot Orthosis

被引:35
作者
Froberg, Asa [1 ]
Komi, Paavo [2 ]
Ishikawa, Masaki [3 ]
Movin, Tomas [1 ]
Arndt, Anton [1 ]
机构
[1] Karolinska Inst, Dept Clin Sci Intervent & Technol, Div Orthoped Surg, S-14186 Stockholm, Sweden
[2] Univ Jyvaskyla, Dept Biol Phys Activ, Neuromuscular Res Ctr, SF-40100 Jyvaskyla, Finland
[3] Osaka Univ Hlth & Sport Sci, Osaka, Japan
关键词
Achilles tendon loading; ankle foot orthosis (AFO); electromyography (EMG); locomotion; FUNCTIONAL TREATMENT; FIBEROPTIC MEASUREMENT; SURGICAL REPAIR; OPTIC FIBER; IMMOBILIZATION; RUPTURE; MUSCLE; WEIGHTBEARING;
D O I
10.1177/0363546508330126
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Ankle foot orthoses are used for postoperative treatment of Achilles tendon ruptures and decrease calf muscle electromyography activity during walking. Hypothesis: Achilles tendon load decreases with increased restriction of dorsiflexion and is associated with decreased triceps surae activity. Study Design: Controlled laboratory study. Methods: In 8 subjects, the maximum force and rate of force development in the Achilles tendon were measured with an optic fiber technique, and the activity of the gastrocnemius, soleus, and tibialis anterior muscles was recorded using electromyography. Trial conditions were walking barefoot and wearing an ankle-foot orthoses set in 3 different positions: (1) locked at 20 degrees of plantar flexion and with free plantar flexion but restricted dorsiflexion to (2) 10 degrees plantar flexion and (3) 10 degrees dorsiflexion, respectively. The design of the ankle foot orthoses did not provide heel support when fixed in a plantarflexed position. Results: Maximum Achilles tendon force was highest at the ankle-foot orthoses setting of 20 degrees plantar flexion (3.1 times body weight) and decreased to 2.1 times body weight during barefoot walking (P < .01). The rate of Achilles tendon force showed an increasing trend with less-restricted dorsiflexion. Soleus activity was 52% of mean barefoot walking activity at 3 20 degrees plantar flexion (P < .001) and then increased as dorsiflexion was less restricted. Conclusion: Weightbearing in ankle-foot orthoses when dorsiflexion is restricted beyond neutral may result in increased forces in the Achilles tendon compared with barefoot walking, despite reduced electromyography activity in the triceps surae and decreased rate of force development.
引用
收藏
页码:1200 / 1207
页数:8
相关论文
共 24 条
  • [1] The relative stress on the Achilles tendon during ambulation in an ankle immobiliser: implications for rehabilitation after Achilles tendon repair
    Akizuki, KH
    Gartman, EJ
    Nisonson, B
    Ben-Avi, S
    McHugh, MP
    [J]. BRITISH JOURNAL OF SPORTS MEDICINE, 2001, 35 (05) : 329 - 333
  • [2] Akizuki KH, 2001, BRIT J SPORT MED, V35, P333
  • [3] Early active motion and weightbearing after cross-stitch Achilles tendon repair
    Aoki, M
    Ogiwara, N
    Ohta, T
    Nabeta, Y
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1998, 26 (06) : 794 - 800
  • [4] Individual muscle contributions to the in vivo Achilles tendon force
    Arndt, AN
    Komi, PV
    Brüggemann, GP
    Lukkariniemi, J
    [J]. CLINICAL BIOMECHANICS, 1998, 13 (07) : 532 - 541
  • [5] BENUM P, 1984, European Surgical Research, V16, P14, DOI 10.1159/000128616
  • [6] BOOTH FW, 1982, J APPL PHYSIOL, V52, P1113
  • [7] Randomised controlled trials of immediate weight-bearing mobilisation for rupture of the tendo Achillis
    Costa, ML
    MacMillan, K
    Halliday, D
    Chester, R
    Shepstone, L
    Robinson, AHN
    Donell, ST
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (01): : 69 - 77
  • [8] Fiberoptic measurement of tendon forces is influenced by skin movement artifact
    Erdemir, A
    Hamel, AJ
    Piazza, SJ
    Sharkey, NA
    [J]. JOURNAL OF BIOMECHANICS, 2003, 36 (03) : 449 - 455
  • [9] Influence of loading rate and cable migration on fiberoptic measurement of tendon force
    Erdemir, A
    Piazza, SJ
    Sharkey, NA
    [J]. JOURNAL OF BIOMECHANICS, 2002, 35 (06) : 857 - 862
  • [10] Achilles tendon loading during walking: application of a novel optic fiber technique
    Finni, T
    Komi, PV
    Lukkariniemi, J
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1998, 77 (03) : 289 - 291