A method for calcium quantification by means of CT coronary angiography using 64-multidetector CT: very high correlation with agatston and volume scores

被引:40
作者
Glodny, Bernhard [1 ]
Helmel, Bettina [1 ]
Trieb, Thomas [1 ]
Schenk, Claudia [1 ]
Taferner, Bernadette [1 ]
Unterholzner, Verena [1 ]
Strasak, Alexander [2 ]
Petersen, Johannes [1 ]
机构
[1] Innsbruck Med Univ, Dept Radiol, A-6020 Innsbruck, Austria
[2] Innsbruck Med Univ, Dept Med Stat Informat & Hlth Econ, A-6020 Innsbruck, Austria
关键词
Multidetector computed tomography; Coronary calcium scoring; Coronary artery disease; Radiation dosage; Cardiac CT; Coronary angiography; ELECTRON-BEAM CT; MULTISLICE COMPUTED-TOMOGRAPHY; MULTIDETECTOR ROW CT; ARTERY CALCIUM; HEART-RATE; CALCIFICATION; REPRODUCIBILITY; AGREEMENT; PHANTOM;
D O I
10.1007/s00330-009-1345-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To find out whether calcium scoring of the coronary arteries (CAC scoring) could be carried out with a CT angiography of the coronary arteries (CTCA) in a single CT data acquisition. The Agatston and V130 scores for 113 patients were assessed. A calcium volume score (V600 score) was compiled from the CTCA data sets. Intra- and interobserver correlations were excellent (rho > 0.97). The intra- and interobserver repeatability coefficients were extremely low, increasing in magnitude from the V600 score to the V130 and Agatston scores. The V600 score underestimates the coronary calcium burden. However, it has a linear relation to the Agatston and V130 scores. Thus, they are predictable from the values of the V600 score. The V600 score shows a linear relation to the classic CAC scores. Due to its extremely high reliability, the score may be a feasible alternative for classic CAC scoring methods in order to reduce radiation dosages.
引用
收藏
页码:1661 / 1668
页数:8
相关论文
共 33 条
[1]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[2]   CONSTRUCTION OF AGE-RELATED REFERENCE CENTILES USING ABSOLUTE RESIDUALS [J].
ALTMAN, DG .
STATISTICS IN MEDICINE, 1993, 12 (10) :917-924
[3]  
[Anonymous], 1994, 57251 ISO
[4]  
[Anonymous], HEART DIS STROK STAT
[5]  
[Anonymous], 2004, WORLD HLTH REPORT 20
[6]   Coronary artery calcium measurement: Agreement of multirow detector and electron beam CP [J].
Becker, CR ;
Kleffel, T ;
Crispin, A ;
Knez, A ;
Young, J ;
Schoepf, UJ ;
Haberl, R ;
Reiser, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) :1295-1298
[7]   Applying the right statistics: analyses of measurement studies [J].
Bland, JM ;
Altman, DG .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (01) :85-93
[8]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[9]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[10]  
*BRIT STAND I, 1975, 957 BS BSI 1