32-Channel 3 tesla receive-only phased-array head coil with soccer-ball element geometry

被引:322
作者
Wiggins, G. C.
Triantafyllou, C.
Potthast, A.
Reykowski, A.
Nittka, M.
Wald, L. L.
机构
[1] Massachusetts Gen Hosp, AA Martinos Ctr Biomed Imaging, Dept Radiol, Boston, MA 02129 USA
[2] Siemens Med Solut, Erlangen, Germany
[3] Invivo Corp, Gainesville, FL USA
关键词
phased array; 32-channel; RF coil design; SNR; g-factor;
D O I
10.1002/mrm.20925
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A 32-channel 3T receive-only phased-array head coil was developed for human brain imaging. The helmet-shaped array was designed to closely fit the head with individual overlapping circular elements arranged in patterns of hexagonal and pentagonal symmetry similar to that of a soccer ball. The signal-to-noise ratio (SNR) and noise amplification (g-factor) in accelerated imaging applications were quantitatively evaluated in phantom and human images and compared with commercially available head coils. The 32-channel coil showed SNR gains of up to 3.5-fold in the cortex and 1.4-fold in the corpus callosum compared to a (larger) commercial eight-channel head coil. The experimentally measured g-factor performance of the helmet array showed significant improvement compared to the eight-channel array (peak g-factor 59% and 26% of the eight-channel values for four- and fivefold acceleration). The performance of the arrays is demonstrated in high-resolution and highly accelerated brain images.
引用
收藏
页码:216 / 223
页数:8
相关论文
共 21 条
[1]  
*BRIT STAND ORG, 1995, 960 BS EN BRIT STAND
[2]   Signal-to-noise ratio and parallel Imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla [J].
de Zwart, JA ;
Ledden, PJ ;
van Gelderen, P ;
Bodurka, J ;
Chu, RX ;
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) :22-26
[3]   Design of a SENSE-optimized high-sensitivity MRI receive coil for brain imaging [J].
de Zwart, JA ;
Ledden, PJ ;
Kellman, P ;
van Gelderen, P ;
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1218-1227
[4]   ELECTRONIC DECOUPLING OF SURFACE-COIL RECEIVERS FOR NMR IMAGING AND SPECTROSCOPY [J].
EDELSTEIN, WA ;
HARDY, CJ ;
MUELLER, OM .
JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (01) :156-161
[5]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[6]   VOLUME IMAGING WITH MR PHASED-ARRAYS [J].
HAYES, CE ;
HATTES, N ;
ROEMER, PB .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :309-319
[7]   NOISE PERFORMANCE OF SURFACE COILS FOR MAGNETIC-RESONANCE IMAGING AT 1.5-T [J].
HAYES, CE ;
AXEL, L .
MEDICAL PHYSICS, 1985, 12 (05) :604-607
[8]   COMPUTER MODELING OF SURFACE COIL SENSITIVITY [J].
LAWRY, TJ ;
WEINER, MW ;
MATSON, GB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :294-302
[9]   64-channel array coil for single echo acquisition magnetic resonance imaging [J].
McDougall, MP ;
Wright, SM .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) :386-392
[10]  
Moeller S, 2004, P 12 ANN M ISMRM KYO, P2388