Assessment of effective dose from concomitant exposures required in verification of the target volume in radiotherapy

被引:27
作者
Waddington, SP [1 ]
McKenzie, AL
机构
[1] Univ W England, Fac Hlth & Social Care, Bristol BS16 1DD, Avon, England
[2] Bristol Haematol & Oncol Ctr, Dept Med Phys & Bioengn, Bristol BS2 8ED, Avon, England
关键词
D O I
10.1259/bjr/67235257
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The requirement of the Ionising Radiation (Medical Exposure) Regulation 2000 [IR(ME)R] of justifying all exposures to ionizing radiation includes those from radiotherapy double exposure portal images resulting in exposure to normal tissues outside the treatment volume. Typical effective doses were calculated for a range of common sites using CT data to outline those parts of specific organs subject to concomitant radiation and generate dose-volume histograms. The product of the mean dose and the relative probability of inducing a fatal cancer in specific organs was used to determine a representative total effective dose in mSv per monitor unit for each site. A table of representative effective doses, ranging from 0.32 mSv to 2.56 mSv per monitor unit, was produced, which may be used to monitor cumulative effective doses of individual patients from double exposure portal images, in addition to those received from localization procedures.
引用
收藏
页码:557 / 561
页数:5
相关论文
共 21 条
[1]   Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate [J].
Alasti, H ;
Petric, MP ;
Catton, CN ;
Warde, PR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03) :869-884
[2]   Prostate target volume variations during a course of radiotherapy [J].
Antolak, JA ;
Rosen, II ;
Childress, CH ;
Zagars, GK ;
Pollack, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (03) :661-672
[3]   Electronic portal imaging devices: a review and historical perspective of contemporary technologies and research [J].
Antonuk, LE .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (06) :R31-R65
[4]   A double exposed portal image comparison between electronic portal imaging hard copies and port films in radiation therapy treatment setup confirmation to determine its clinical application in a radiotherapy center [J].
Hatherly, KE ;
Smylie, JC ;
Rodger, A ;
Dally, MJ ;
Davis, SR ;
Millar, JL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (01) :191-198
[5]   Set-up verification using portal imaging; review of current clinical practice [J].
Hurkmans, CW ;
Remeijer, P ;
Lebesque, JV ;
Mijnheer, BJ .
RADIOTHERAPY AND ONCOLOGY, 2001, 58 (02) :105-120
[6]  
Institute of Physics and Engineering in Medicine, 2002, MED DENT GUID NOT
[7]  
*INT COMM RAD PRO, 1975, ICRP PUBL, V23
[8]  
*INT COMM RAD PROT, 2001, 2 ICRP
[9]  
International Commission on Radiological Protection, 2002, ICRP PUBL, V89
[10]  
International Commission on Radiological Protection, 1991, ICRP PUBL