Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers

被引:50
作者
Blythe, Murray
Stoffel, Karl
Jarrett, Paul
Kuster, Markus
机构
[1] Univ Western Australia, Fremantle Orthopaed Unit, Fremantle, WA, Australia
[2] Kantonsspital St Gallen, Dept Orthopaed, St Gallen, Switzerland
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2006年 / 31A卷 / 10期
关键词
biomechanics; distal radius fracture; internal fixation; locking plate;
D O I
10.1016/j.jhsa.2006.09.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To compare the stability and stiffness of dorsal and volar fixed-angle distal radius constructs in a cadaveric model. Methods: A locking distal radius system was used in a combination of a dorsal and styloid plate (group 1), a single volar plate (group 2), and a combination of a volar and styloid plate (group 3) configuration. In addition a single volar 3.5-mm steel locking plate was used in group 4. Each construct was tested on 6 fresh-frozen radii with simulated unstable dorsally comminuted extra-articular distal radius fractures. Specimens were tested on a material testing machine with an extensometer and subjected to axial compression fatigue and load-to-failure testing. Results: No construct failed in fatigue testing of 250 N for 5,000 cycles. Two specimens in each group were tested for 20,000 cycles without failure. The plastic deformation in the double-plate groups was lower compared with the single-plate groups, although the difference was not statistically significant. Group 1 had the highest and group 4 the lowest failure load and stiffness, respectively. The differences between group 1 and the other groups, except failure load compared with group 3, were statistically significant. Groups 2 and 3 had a significantly higher load to failure and group 3 had a significantly higher stiffness compared with group 4. Conclusions: All constructs offer adequate stability with minimal deformation on fatigue testing under physiologic conditions. Dorsal fixed-angle constructs are stiffer and stronger than volar constructs. The addition of a styloid plate to a volar plate did not significantly improve stability in this model of simulated extra-articular dorsal comminution loaded in axial compression.
引用
收藏
页码:1587 / 1593
页数:7
相关论文
共 21 条
[1]
OPEN REDUCTION AND INTERNAL-FIXATION OF COMMINUTED, INTRAARTICULAR FRACTURES OF THE DISTAL RADIUS [J].
AXELROD, TS ;
MCMURTRY, RY .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1990, 15A (01) :1-11
[2]
Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: A multicenter study of 73 fractures [J].
Carter, PR ;
Frederick, HA ;
Laseter, GF .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (02) :300-307
[3]
Constantine KJ, 2002, ORTHOPEDICS, V25, P125
[4]
Dunning CE, 1999, J HAND SURG-AM, V24A, P992
[5]
DESIGN AND BIOMECHANICS OF A PLATE FOR THE DISTAL RADIUS [J].
GESENSWAY, D ;
PUTNAM, MD ;
MENTE, PL ;
LEWIS, JL .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1995, 20A (06) :1021-1027
[6]
Open reduction and internal fixation of displaced intraarticular fractures of the distal radius - 31 patients followed for 3-7 years [J].
Hove, LM ;
Nilsen, PT ;
Furnes, O ;
Oulie, HE ;
Solheim, E ;
Molster, AO .
ACTA ORTHOPAEDICA SCANDINAVICA, 1997, 68 (01) :59-63
[7]
Fractures of the distal radius treated by internal fixation and early function - A prospective study of 73 consecutive patients [J].
Jakob, M ;
Rikli, DA ;
Regazzoni, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (03) :340-344
[8]
KAMANO M, 2002, CLIN ORTHOP RELAT R, V397, P403
[9]
Complications of the AO/ASIF titanium distal radius plate system (π plate) in internal fixation of the distal radius:: A brief report [J].
Kambouroglou, GK ;
Axelrod, TS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (04) :737-741
[10]
Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate - A biomechanical study in a cadaveric model [J].
Leung, F ;
Zhu, L ;
Ho, H ;
Lu, WW ;
Chow, SP .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2003, 28B (03) :263-266