Validation of transit-time flowmetry for chronic measurements of regional blood flow in resting and exercising rats

被引:14
作者
Amaral, SL [1 ]
Michelini, LC [1 ]
机构
[1] UNIV SAO PAULO, ICB, DEPT FISIOL & BIOFIS, BR-05508900 SAO PAULO, SP, BRAZIL
关键词
ultrasonic transit-time; iliac blood flow; renal blood flow; exercise; anesthesia; conscious rats;
D O I
10.1590/S0100-879X1997000700013
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The objective of the present study was to validate the transit-time technique for long-term measurements of iliac and renal blood flow in rats. Flow measured with ultrasonic probes was confirmed ex vivo using excised arteries perfused at varying flow rates. An implanted 1-mm probe reproduced with accuracy different patterns of flow relative to pressure in freely moving rats and accurately quantitated the resting iliac flow value (on average 10.43 +/- 0.99 ml/min or 2.78 +/- 0.3 mi min(-1) 100 g body weight(-1)). The measurements were stable over an experimental period of one week but were affected by probe size (resting flows were underestimated by 57% with a 2-mm probe when compared with a I-mm probe) and by anesthesia (in the same rats, iliac flow was reduced by 50-60% when compared to the conscious state). Instantaneous changes of iliac and renal flow during exercise and recovery were accurately measured by the transit-time technique. Iliac flow increased instantaneously at the beginning of mild exercise (from 12.03 +/- 1.06 to 25.55 +/- 3.89 ml/min at 15 s) and showed a smaller increase when exercise intensity increased further, reaching a plateau of 38.43 +/- 1.92 ml/min at the 4th min of moderate exercise intensity. In contrast, exercise-induced reduction of renal flow was smaller and slower, with 18% and 25% decreases at mild and moderate exercise intensities, Our data indicate that transit-time flowmetry is a reliable method for long-term and continuous measurements of regional blood flow at rest and can be used to quantitate the dynamic flow changes that characterize exercise and recovery.
引用
收藏
页码:897 / 908
页数:12
相关论文
共 30 条
[1]   EXERCISE BLOOD-FLOW PATTERNS WITHIN AND AMONG RAT MUSCLES AFTER TRAINING [J].
ARMSTRONG, RB ;
LAUGHLIN, MH .
AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 246 (01) :H59-H68
[2]  
BARNES RJ, 1983, J PHYSIOL-LONDON, V345, pP2
[3]   EVALUATION OF A TRANSIT-TIME SYSTEM FOR THE CHRONIC MEASUREMENT OF BLOOD-FLOW IN CONSCIOUS SHEEP [J].
BEDNARIK, JA ;
MAY, CN .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 78 (02) :524-530
[4]   LONG-TERM CONTROL OF ARTERIAL BLOOD-PRESSURE [J].
COWLEY, AW .
PHYSIOLOGICAL REVIEWS, 1992, 72 (01) :231-300
[5]   VALIDATION OF 1-MM AND 2-MM TRANSIT-TIME ULTRASOUND FLOW PROBES ON MESENTERIC-ARTERY AND AORTA OF RATS [J].
DALMEIDA, MS ;
GAUDIN, C ;
LEBREC, D .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 268 (03) :H1368-H1372
[6]   DIFFERENTIAL HEMODYNAMIC-RESPONSES TO SELECTIVE INHIBITORS OF CYCLIC-NUCLEOTIDE PHOSPHODIESTERASES IN CONSCIOUS RATS [J].
DUNDORE, RL ;
HABEEB, PG ;
PRATT, PF ;
BECKER, LT ;
CLAS, DM ;
BUCHHOLZ, RA .
JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 1992, 19 (06) :937-944
[7]  
FRAGEN RJ, 1986, CARDIOVASCULAR ACTIO, V1, P51
[8]   CARDIOVASCULAR EFFECTS OF NEURONAL ACTIVATION OF THE EXTENDED AMYGDALA IN RATS [J].
GELSEMA, AJ ;
COPELAND, NE ;
DROLET, G ;
BACHELARD, H .
BRAIN RESEARCH, 1993, 626 (1-2) :156-166
[9]  
GOREWIT RC, 1989, J DAIRY SCI, V72, P116
[10]   EFFECT OF PERIVASCULAR ELECTROMAGNETIC FLOW PROBES ON PULMONARY HEMODYNAMICS [J].
GRANT, BJB ;
PARADOWSKI, LJ ;
FITZPATRICK, JM .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 65 (04) :1885-1890