Clinical assessment of aortic stenosis (AS) is sometimes challenging, because all hemodynamic indexes of severity are modified by flow rate. However, the mechanisms underlying flow dependence remain controversial. Analysis of instantaneous flow dynamics has provided crucial information in a number of cardiovascular disorders and may add new insight into this phenomenon. This study was designed to analyze in vivo the effects of flow interventions on instantaneous valvular dynamics of stenotic valves. For this purpose, a custom algorithm for signal processing of Doppler spectrograms was developed and validated against a control population. Digital Doppler recordings at the aortic valve and left ventricular outflow tract were obtained in 15 patients with AS, at baseline and during low-dose dobutamine infusion; 10 normal subjects were studied as controls. Spectrograms were processed by signal averaging, time alignment, modal-velocity enhancement, envelope tracing, and numerical interpolation. Instantaneous relative aortic valve area (rAVA) was obtained by the continuity equation and plotted against normalized ejection time. Curves were classified as either type A (rapid, early-systolic opening) or type B (slow, end-systolic opening). Curves from controls closely matched prior knowledge of normal valve dynamics, but curves from patients were clearly different: all controls except 2 (80%) had type A, whereas all patients except 3 (80%) had a type B pattern (p = 0.03). Dobutamine infusion in patients increased and slightly anticipated peak rAVA by accelerating valve opening. Despite similar values of area and pressure difference, type B dynamics were associated with lower blood pressure (p = 0.01) and worse long-term outcome (>3 years) than type A flow dynamics (p = 0.02). Signal processing of Doppler spectrograms allows a comprehensive assessment of aortic flow dynamics. Differences in timing of valve aperture and in maximal leaflet excursion account for flow-mediated changes in valve area, suggesting complementary effects of inertia and elasticity on the kinetics of stenotic aortic valves. Flow-dynamic analysis provides novel clinical information regarding physiology of AS unavailable to conventional indexes. (C)2000 by Excerpta Medica, Inc.
引用
收藏
页码:611 / 617
页数:7
相关论文
共 30 条
[1]   Variation of anatomic valve area during ejection in patients with valvular aortic stenosis evaluated by two-dimensional echocardiographic planimetry: Comparison with traditional Doppler data [J].
Arsenault, M ;
Masani, N ;
Magni, G ;
Yao, JF ;
Deras, L ;
Pandian, N .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (07) :1931-1937
[2]   Changes in effective aortic valve area during ejection in adults with aortic stenosis [J].
Badano, L ;
Cassottana, P ;
Bertoli, D ;
Carratino, L ;
Lucatti, A ;
Spirito, P .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (09) :1023-1028
[3]  
BELLHOUS.B, 1969, CIRC RES, V25, P693
[4]   Effects of dobutamine on Doppler echocardiographic indexes of aortic stenosis [J].
Bermejo, J ;
GarciaFernandez, MA ;
Torrecilla, EG ;
Bueno, H ;
Moreno, MM ;
SanRoman, D ;
Delcan, JL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (05) :1206-1213
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   FLOW DEPENDENCE OF MEASURES OF AORTIC-STENOSIS SEVERITY DURING EXERCISE [J].
BURWASH, IG ;
PEARLMAN, AS ;
KRAFT, CD ;
MIYAKEHULL, C ;
HEALY, NL ;
OTTO, CM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (05) :1342-1350
[7]   ECHOCARDIOGRAPHIC VOLUME FLOW AND STENOSIS SEVERITY MEASURES WITH CHANGING FLOW-RATE IN AORTIC-STENOSIS [J].
BURWASH, IG ;
FORBES, AD ;
SADAHIRO, M ;
VERRIER, ED ;
PEARLMAN, AS ;
THOMAS, R ;
KRAFT, C ;
OTTO, CM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 265 (05) :H1734-H1743
[8]   FLUID-MECHANICS OF AORTIC-STENOSIS .1. THEORY AND STEADY FLOW EXPERIMENTS [J].
CLARK, C .
JOURNAL OF BIOMECHANICS, 1976, 9 (08) :521-528
[9]   Analysis of the effect of flow rate on the Doppler continuity equation for stenotic orifice area calculations - A numerical study [J].
DeGroff, CG ;
Shandas, R ;
Valdes-Cruz, L .
CIRCULATION, 1998, 97 (16) :1597-1605
[10]   HYDRAULIC FORMULA FOR CALCULATION OF THE AREA OF THE STENOTIC MITRAL VALVE, OTHER CARDIAC VALVES, AND CENTRAL CIRCULATORY SHUNTS .1. [J].
GORLIN, R ;
GORLIN, SG .
AMERICAN HEART JOURNAL, 1951, 41 (01) :1-29