Optimization of a flat-panel based real time dual-energy system for cardiac imaging

被引:21
作者
Ducote, Justin L. [1 ]
Xu, Tong [1 ]
Molloi, Sabee [1 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92697 USA
关键词
D O I
10.1118/1.2174131
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
A simulation study was conducted to evaluate the effects of high-energy beam filtration, dual-gain operation and noise reduction on dual-energy images using a digital flat-panel detector. High-energy beam filtration increases image contrast through greater beam separation and tends to reduce total radiation exposure and dose per image pair. It is also possible to reduce dual-energy image noise by acquiring low and high-energy images at two different detector gains. In addition, dual-energy noise reduction algorithms can further reduce image noise. The cumulative effect of these techniques applied in series was investigated in this study. The contrast from a small thickness of calcium was simulated over a step phantom of tissue equivalent material with a CsI phosphor as the image detector. The dual-energy contrast-to-noise ratio was calculated using values of energy absorption and energy variance. A figure-of-merit (FOM) was calculated from dual-energy ratio (CNR) and patient effective dose estimated from values of entrance exposure. Filter atomic numbers in the range of 1-100 were considered with thicknesses ranging from 0-2500 mg/cm(2). The simulation examined combinations of the above techniques which maximized the FOM. The application of a filter increased image contrast by as much as 45%. Near maximal increases were seen for filter atomic numbers in the range of 40-60 and 85-100 with masses above 750 mg/cm(2). Increasing filter thickness beyond 1000 mg/cm2 increased tube loading without further significant contrast enhancement. No additional FOM improvements were seen with dual gain before or after the application of any noise reduction algorithm. Narrow beam experiments were carried out to verify predictions. The measured FOM increased by more than a factor of 3.5 for a silver filter thickness of 800 mu m, equal energy weighting and application of a noise clipping algorithm. The main limitation of dynamic high-energy filtration is increased tube loading. The results of this study can be used to help develop an optimal dual-energy imaging system. (C) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:1562 / 1568
页数:7
相关论文
共 15 条
[1]
Comparison of dual energy detector system performance [J].
Alvarez, RE ;
Seibert, JA ;
Thompson, SK .
MEDICAL PHYSICS, 2004, 31 (03) :556-565
[2]
Accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV [J].
Boone, JM ;
Seibert, JA .
MEDICAL PHYSICS, 1997, 24 (11) :1661-1670
[3]
Comparison of x-ray cross sections for diagnostic and therapeutic medical physics [J].
Boone, JM ;
Chavez, AE .
MEDICAL PHYSICS, 1996, 23 (12) :1997-2005
[4]
HINSHAW DA, 1995, P SOC PHOTO-OPT INS, V2432, P134, DOI 10.1117/12.208330
[5]
HETEROPLASMY OF CHLOROPLAST DNA IN MEDICAGO [J].
JOHNSON, LB ;
PALMER, JD .
PLANT MOLECULAR BIOLOGY, 1989, 12 (01) :3-11
[6]
AN ALGORITHM FOR NOISE SUPPRESSION IN DUAL ENERGY CT MATERIAL DENSITY IMAGES [J].
KALENDER, WA ;
KLOTZ, E ;
KOSTARIDOU, L .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (03) :218-224
[7]
LEHERON JC, 1992, PHYS MED BIOL, V37, P2117, DOI 10.1088/0031-9155/37/11/008
[8]
A CORRELATED NOISE-REDUCTION ALGORITHM FOR DUAL-ENERGY DIGITAL SUBTRACTION ANGIOGRAPHY [J].
MCCOLLOUGH, CH ;
VANLYSEL, MS ;
PEPPLER, WW ;
MISTRETTA, CA .
MEDICAL PHYSICS, 1989, 16 (06) :873-880
[9]
QUANTIFICATION TECHNIQUES FOR DUAL-ENERGY CARDIAC IMAGING [J].
MOLLOI, SY ;
MISTRETTA, CA .
MEDICAL PHYSICS, 1989, 16 (02) :209-217
[10]
NOISE-REDUCTION METHODS FOR HYBRID SUBTRACTION [J].
NISHIMURA, DG ;
MACOVSKI, A ;
BRODY, WR .
MEDICAL PHYSICS, 1984, 11 (03) :259-265