Applications for multifrequency ultrasound biomicroscopy in mice from implantation to adulthood

被引:94
作者
Zhou, YQ
Foster, FS
Qu, DW
Zhang, M
Harasiewicz, KA
Adamson, SL
机构
[1] Mt Sinai Hosp, Samuel Lunenfeld Res Inst, Toronto, ON M5G 1X5, Canada
[2] Univ Toronto, Sunnybrook & Womens Coll Hlth Sci Ctr, Toronto, ON M5G 1X5, Canada
[3] Univ Toronto, Dept Obstet Gynecol, Toronto, ON M5G 1X5, Canada
[4] Univ Toronto, Dept Physiol, Toronto, ON M5G 1X5, Canada
[5] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 1X5, Canada
关键词
Doppler; heart; placenta; embryo; newborn; development; aorta; umbilical cord; kidney; mouse; biomicroscope; carotid artery; juvenile; blood velocity; heart valves;
D O I
10.1152/physiolgenomics.00119.2001
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
A new multifrequency (19-55 MHz) ultrasound biomicroscope with two-dimensional imaging and integrated Doppler ultrasound was evaluated using phantoms and isoflurane-anesthetized mice. Phantoms revealed the biomicroscope's lateral resolution was between 50 and 100 mum, whereas that of a conventional 13 MHz ultrasound system was 200-500 mum. This difference was apparent in the markedly higher resolution images achieved using the biomicroscope in vivo. Transcutaneous images of embryos in pregnant mice from similar to2 days after implantation (7 days gestation) to near term (17.5 days) were obtained using frequencies from 25 to 40 MHz. The ectoplacental cone and early embryonic cavities were visible as were the placenta and embryonic organs throughout development to term. We also evaluated the ability of the biomicroscope to detect important features of heart development by examining embryos from 8.5 to 17.5 day gestation in exteriorized uteri using 55 MHz ultrasound. Cardiac looping, division of the outflow tract, and ventricular septation were visible. In postnatal imaging, we observed the heart and kidney of neonatal mice at 55 MHz, the carotid artery in juveniles (similar to8 g body wt) and adults (similar to25 g body wt) at 40 MHz, and the adult heart, aorta, and kidney at 19 MHz. The coefficient of variation of carotid and aortic diameter measurements was 1-3%. In addition, blisters in GRIP1 -/- embryos and aortic valvular stenosis in two adults were readily visualized. Using image-guided Doppler function, low blood velocities in vessels as small as 100 mum in diameter including the primitive heart tube at day 8.5 were measurable, but high blood velocities (>37.5 cm/s) such as in the heart and large arteries in late gestation and postnatal life were off-scale. Accurate cardiac dimension measurements were impeded by poor temporal resolution (4 frames/s). In summary, the multifrequency ultrasound biomicroscope is a versatile tool well suited to detailed study of the morphology of various organ systems throughout development in mice and for hemodynamic measurements in the low velocity range.
引用
收藏
页码:113 / 126
页数:14
相关论文
共 39 条
[1]   40-MHz echocardiography scanner for cardiovascular assessment of mouse embryos [J].
Aristizábal, O ;
Christopher, DA ;
Foster, FS ;
Turnbull, DH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (09) :1407-1417
[2]   IDENTIFICATION OF MECHANISMS RESPONSIBLE FOR FETAL WEIGHT-REDUCTION IN MICE FOLLOWING ULTRASOUND EXPOSURE [J].
BARNETT, SB ;
WILLIAMS, AR .
ULTRASONICS, 1990, 28 (03) :159-165
[3]   International recommendations and guidelines for the safe use of diagnostic ultrasound in medicine [J].
Barnett, SB ;
Ter Haar, GR ;
Ziskin, MC ;
Rott, HD ;
Duck, FA ;
Maeda, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (03) :355-366
[4]   The sensitivity of biological tissue to ultrasound [J].
Barnett, SB ;
Rott, HD ;
terHaar, GR ;
Ziskin, MC ;
Maeda, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (06) :805-812
[5]   Epidermolysis bullosa and embryonic lethality in mice lacking the multi-PDZ domain protein GRIP1 [J].
Bladt, F ;
Tafuri, A ;
Gelkop, S ;
Langille, L ;
Pawson, T .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (10) :6816-6821
[6]  
Coatney R W, 2001, ILAR J, V42, P233
[7]   DEATH BEFORE BIRTH - CLUES FROM GENE KNOCKOUTS AND MUTATIONS [J].
COPP, AJ .
TRENDS IN GENETICS, 1995, 11 (03) :87-93
[8]   Neonatal cardiomyopathy in mice homozygous for the Arg403Gln mutation in the α cardiac myosin heavy chain gene [J].
Fatkin, D ;
Christe, ME ;
Aristizabal, O ;
McConnell, BK ;
Srinivasan, S ;
Schoen, FJ ;
Seidman, CE ;
Turnbull, DH ;
Seidman, JG .
JOURNAL OF CLINICAL INVESTIGATION, 1999, 103 (01) :147-153
[9]   Advances in ultrasound biomicroscopy [J].
Foster, FS ;
Pavlin, CJ ;
Harasiewicz, KA ;
Christopher, DA ;
Turnbull, DH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (01) :1-27
[10]   A method for rapid gain-of-function studies in the mouse embryonic nervous system [J].
Gaiano, N ;
Kohtz, JD ;
Turnbull, DH ;
Fishell, G .
NATURE NEUROSCIENCE, 1999, 2 (09) :812-819