Voltammetric determination of alkaline phosphatase and horseradish peroxidase activity using 3-indoxyl phosphate as substrate -: Application to enzyme immunoassay

被引:31
作者
Fanjul-Bolado, P [1 ]
González-García, MB [1 ]
Costa-García, A [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, E-33006 Oviedo, Spain
关键词
horseradish peroxidase; alkaline phosphatase; 3-indoxyl phosphate; screen-printed carbon electrodes; ELISA; cyclic voltammetry;
D O I
10.1016/j.talanta.2004.03.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of 3-indoxyl phosphate (3-IP) as an electrochemical substrate for ELISAs with voltammetric detection was investigated. Indirect measurements of alkaline phosphatase (AP) and horseradish peroxidase (HRP) activity in solution were carried out. Picomolar levels of both enzymes can be detected, which enables the design of electrochemical immunoassays using this substrate. The enzymatic turnover of the substrate gives indigo blue, insoluble in aqueous solutions. This product is easily converted into its soluble parent compound, indigo carmine (IC), by addition of fuming sulphuric acid to the reaction media. IC shows a reversible voltammetric peak at the formal potential of -0.15 V (versus Ag pseudo-reference electrode) when a screen-printed carbon electrode (SPCE) is used. The peak current of this process constitutes the analytical signal. Using this approach an ELISA assay to quantify pneumolysin (PLY, a toxin related to respiratory infections) was carried out using AP or HRP as enzymatic label. Calibration plots obtained are reported. 3-IP is demonstrated to be the first suitable substrate for the two most common enzyme labels used in immunoassays. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:452 / 457
页数:6
相关论文
共 31 条
[11]  
2-C
[12]   Indirect determination of alkaline phosphatase based on the amperometric detection of indigo carmine at a screen-printed electrode in a flow system [J].
Díaz-González, M ;
Fernández-Sánchez, C ;
Costa-García, A .
ANALYTICAL SCIENCES, 2002, 18 (11) :1209-1213
[13]   AMPLIFIED MASS IMMUNOSORBENT-ASSAY WITH A QUARTZ CRYSTAL MICROBALANCE [J].
EBERSOLE, RC ;
WARD, MD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1988, 110 (26) :8623-8628
[14]  
Fernandez Bobes Cecilia, 2001, Electroanalysis, V13, P559
[15]   Competitive enzyme immunosensor developed on a renewable carbon paste electrode support [J].
Fernández-Sánchez, C ;
Costa-García, A .
ANALYTICA CHIMICA ACTA, 1999, 402 (1-2) :119-127
[16]   AC voltammetric carbon paste-based enzyme immunosensors [J].
Fernández-Sánchez, C ;
González-García, MB ;
Costa-García, A .
BIOSENSORS & BIOELECTRONICS, 2000, 14 (12) :917-924
[17]  
Fernandez-Sanchez C, 1998, ELECTROANAL, V10, P249, DOI 10.1002/(SICI)1521-4109(199804)10:4<249::AID-ELAN249>3.0.CO
[18]  
2-C
[19]   Differential pulse voltammetric enzyme-linked immunoassay for the determination of Helicobacter pylori specific immunoglobulin G (IgG) antibody [J].
He, YN ;
Chen, HY ;
Zheng, JJ ;
Zhang, GY ;
Chen, ZL .
TALANTA, 1997, 44 (05) :823-830
[20]   Immunosensors for pesticide determination in natural waters [J].
Mallat, E ;
Barceló, D ;
Barzen, C ;
Gauglitz, G ;
Abuknesha, R .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (03) :124-132