Biomechanical Properties of the Cornea in Fuchs' Corneal Dystrophy

被引:77
作者
del Buey, Maria A. [1 ]
Cristobal, Jose A. [1 ]
Ascaso, Francisco J. [1 ]
Lavilla, Laura [1 ]
Lanchares, Elena [2 ]
机构
[1] Univ Clin Hosp, Dept Ophthalmol, ES-50009 Zaragoza, Spain
[2] Univ Zaragoza, Inst Aragones Salud, CIBER Bioingn Biomat & Nanomed, Zaragoza, Spain
基金
瑞典研究理事会;
关键词
OCULAR RESPONSE ANALYZER; INTRAOCULAR-PRESSURE; KERATOCONIC EYES; THICKNESS;
D O I
10.1167/iovs.08-3312
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
PURPOSE. To investigate the effects of Fuchs' corneal dystrophy (FCD) on corneal biomechanical properties and the results of IOP readings in relation to changes in corneal hysteresis (CH) and central corneal thickness (CCT). METHODS. Corneal biomechanical properties, including CH, corneal resistance factor (CRF), and CCT, were measured with the ocular response analyzer (ORA) in 11 eyes of 11 patients with clinically confirmed FCD and 12 eyes of 12 healthy subjects. The ORA was also used to determine the values of intraocular pressure (IOPg) and corneal compensated IOP (IOPcc). Goldmann applanation tonometry (GAT) was also measured. RESULTS. CH measured 10.3 +/- 1.6 mm Hg (range, 8.7-13.8) in normal eyes and 6.9 +/- 1.8 mm Hg (range, 4.6-11.7) in FCD eyes (P = 0.001). CRF in the normal and FCD eyes was 10.5 +/- 1.5 mm Hg (range, 8.5-13.3) and 8.1 +/- 1.9 (range, 4.5-11.2), respectively (P = 0.005). CCT was higher in FCD eyes (606 +/- 20 mu m; range, 578-635) than in normal eyes (538.4 +/- 24.9 mu m; range, 495-575; P = 0.0001). IOPg was 16.2 +/- 2.2 mm Hg (range, 13.5-18.7) in control eyes compared with 17.6 +/- 2.7 mm Hg (range, 12.8-18.6) in FCD eyes (P = 0.201). However, IOP cc in the FCD group (21.8 +/- 4.6 mm Hg; range, 12.8-29.0) was higher than in the control group (16.5 +/- 3.4 mm Hg; range, 11.9-23.9; P = 0.006). GAT in the normal and FCD eyes was 16.7 +/- 2.1 mm Hg (range, 12.8-18.6) and 16.9 +/- 2.3 mm Hg (range, 13.1-19.0), respectively (P = 0.205). CONCLUSIONS. FCD led to a change of corneal biomechanical properties. CH and CRF were significantly lower in FCD eyes than in normal eyes. IOPcc was significantly higher in FCD eyes than in control eyes. These values may be useful in addition to CCT when assessing corneal rigidity. Thus, FCD may cause an underestimation error in IOP measurement. (Invest Ophthalmol Vis Sci. 2009;50:3199-3202) DOI:10.1167/iovs.08-3312
引用
收藏
页码:3199 / 3202
页数:4
相关论文
共 9 条
[1]
Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer [J].
Kotecha, Aachal ;
Elsheikh, Ahmed ;
Roberts, Cynthia R. ;
Zhu, Haogang ;
Garway-Heath, David F. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (12) :5337-5347
[2]
Influence of corneal biomechanical properties on intraocular pressure measurement - Quantitative analysis [J].
Liu, J ;
Roberts, CJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :146-155
[3]
Central corneal thickness and corneal hysteresis during corneal swelling induced by contact lens wear with eye closure [J].
Lu, Fan ;
Xu, Suzhong ;
Qu, Jia ;
Shen, Meixiao ;
Wang, Xiaoxing ;
Fang, Haizhen ;
Wang, Jianhua .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (04) :616-622
[4]
Determining in vivo biomechanical properties of the cornea with an ocular response analyzer [J].
Luce, DA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :156-162
[5]
Evaluation of the influence of corneal biomechanical properties on Intraocular pressure measurements using the Ocular Response Analyzer [J].
Medeiros, Felipe A. ;
Weinreb, Robert N. .
JOURNAL OF GLAUCOMA, 2006, 15 (05) :364-370
[6]
Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes [J].
Ortiz, Dolores ;
Pinero, David ;
Shabayek, Mohamed H. ;
Arnalich-Montiel, Francisco ;
Alio, Jorge L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (08) :1371-1375
[7]
Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes [J].
Shah, Sunil ;
Laiquzzaman, Mohammed ;
Bhojwani, Rajan ;
Mantry, Sanjay ;
Cunliffe, Ian .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (07) :3026-3031
[8]
Biomechanical properties of the cornea in high myopia [J].
Shen, Meixiao ;
Fan, Fan ;
Xue, Anquan ;
Wang, Jianhua ;
Zhou, Xiangtian ;
Lu, Fan .
VISION RESEARCH, 2008, 48 (21) :2167-2171
[9]
Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam study [J].
Wolfs, RC ;
Klaver, CCW ;
Vingerling, JR ;
Grobbee, DE ;
Hofman, A ;
deJong, PTVM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 123 (06) :767-772