Anisotropy of an (192)iridium high dose rate source measured with a miniature ionization chamber

被引:29
作者
Mishra, V [1 ]
Waterman, FM [1 ]
Suntharalingam, N [1 ]
机构
[1] THOMAS JEFFERSON UNIV,JEFFERSON MED COLL,DEPT RADIAT ONCOL,PHILADELPHIA,PA 19107
关键词
high dose rate brachytherapy; Ir-192; anisotropy factor;
D O I
10.1118/1.597983
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The anisotropy of a high dose rate (HDR) Ir-192 source was measured in air and in water using a miniature (0.147 cm(3)) ionization chamber. Measurements were made at a distance of 5 cm from the source center at polar angles from 10 degrees-170 degrees. The anisotropy was found to be less pronounced in water, and the anisotropy is asymmetric about the transverse axis. The results agree with previous ionization chamber and TLD measurements to within +/-4%. Mean anisotropy factors were determined at each angle from all existing data at 5 cm distance, and compared to published Monte Carlo calculations, and to the values used in the microSelectron HDR brachytherapy planning system (BPS). The Monte Carlo photon transport code appears to systematically underestimate the anisotropy factor by up to 4% in the forward direction and overestimate it by up to 3% in the backward direction. The mean anisotropy factors also indicate that the BPS systematically underestimates the anisotropy factor by up to 3% in the forward direction, and overestimates it by up to 15% in the backward direction. However, the 15% difference occurs at 180 degrees where it is not likely to be clinically significant. (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:751 / 755
页数:5
相关论文
共 7 条
[1]  
[Anonymous], INT BRACHYTHERAPY PR
[2]   TLD, diode and monte carlo dosimetry of an Ir-192 source for high dose-rate brachytherapy [J].
Kirov, AS ;
Williamson, JF ;
Meigooni, AS ;
Zhu, Y .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (12) :2015-2036
[3]   EFFECT OF FINITE SIZE OF IONIZATION CHAMBERS ON MEASUREMENTS OF SMALL PHOTON SOURCES [J].
KONDO, S ;
RANDOLPH, ML .
RADIATION RESEARCH, 1960, 13 (01) :37-60
[4]  
MOERLAND MA, 1992, INT BRACHYTHERAPY, P286
[5]   ANISOTROPY MEASUREMENTS OF A HIGH-DOSE-RATE IR-192 SOURCE IN AIR AND IN POLYSTYRENE [J].
MULLERRUNKEL, R ;
CHO, SH .
MEDICAL PHYSICS, 1994, 21 (07) :1131-1134
[6]   MONTE-CARLO AIDED DOSIMETRY OF THE MICROSELECTRON PULSED AND HIGH-DOSE-RATE IR-192 SOURCES [J].
WILLIAMSON, JF ;
LI, ZF .
MEDICAL PHYSICS, 1995, 22 (06) :809-819
[7]  
ZANDONA R, 1995, 7 ACT, P39