Effects of disc height and distractive forces on graft compression in an anterior cervical discectomy model

被引:125
作者
Truumees, E
Demetropoulos, CK
Yang, KH
Herkowitz, HN
机构
[1] William Beaumont Hosp, Royal Oak, MI 48072 USA
[2] Wayne State Univ, Detroit, MI USA
关键词
anterior interbody fusion; biomechanics; cervical spine; corpectomy; endplate graft; mechanics; strut;
D O I
10.1097/00007632-200211150-00005
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. An in vitro biomechanical study using a calibrated distractor and a subminiature load cell in a cadaver anterior cervical discectomy construct was conducted. Objective. To study the interrelations of preoperative disc height, graft height, and compressive, and distractive forces in an anterior cervical discectomy model. Summary of Background Data. the effects of graft size on compressive and distractive forces in a discectomy model remain unknown. Larger grafts afford neutral decompression through anterior column distraction. This distraction may subject the graft and vertebral bodies to excessive loads, increasing graft fracture, and subsidence risk. Methods. Disc height was measured radiographically in 18 specimens. A Smith-Robinson discectomy was performed, and the superior and inferior ends of the specimens were embedded in polyester resin. Distraction was applied through a calibrated Caspar distractor to measure the distractive force applied while steel spacers rigidly fixed to a subminiature load cell were introduced. After distraction was removed, immediate compressive force was measured. Results. Distractive forces of 112.4 N and 189.9 N were required to insert the 6-mm and 8-mm grafts, respectively. When this distractive force was removed, immediate compressive loads of 8.8 N and 21.5 N on the graft were noted. When a compressive load of 45 N was applied in a loading frame, measured graft loads of 16.2 N and 29.2 N also increased. No statistically significant relation was observed between preoperative disc height and distractive force or compressive of the graft. Significantly lower distractive and compressive forces were associated with insertion of the 6-mm rather than 8-mm graft. Conclusions. Significantly higher distractive and compressive forces were recorded with larger grafts. Preoperative disc height was not an accurate predictor of graft loads.
引用
收藏
页码:2441 / 2445
页数:5
相关论文
共 20 条
[1]
PREDICTION OF BONE-GRAFT STRENGTH USING DUAL-ENERGY RADIOGRAPHIC ABSORPTIOMETRY [J].
AN, HS ;
XU, RM ;
LIM, TH ;
MCGRADY, L ;
WILSON, C .
SPINE, 1994, 19 (20) :2358-2363
[2]
IDEAL THICKNESS OF SMITH-ROBINSON GRAFT FOR ANTERIOR CERVICAL FUSION - A CADAVERIC STUDY WITH COMPUTED TOMOGRAPHIC CORRELATION [J].
AN, HS ;
EVANICH, CJ ;
NOWICKI, BH ;
HAUGHTON, VM .
SPINE, 1993, 18 (14) :2043-2047
[3]
THE ROLE OF DISTRACTION IN IMPROVING THE SPACE AVAILABLE FOR THE CORD IN CERVICAL SPONDYLOSIS [J].
BAYLEY, JC ;
YOO, JU ;
KRUGER, DM ;
SCHLEGEL, J .
SPINE, 1995, 20 (07) :771-775
[4]
BROWER RS, 1992, 20 ANN M CERV SPIN R
[5]
Biomechanical evaluation of Caspar and Cervical Spine Locking Plate systems in a cadaveric model [J].
Clausen, JD ;
Ryken, TC ;
Traynelis, VC ;
Sawin, PD ;
Dexter, F ;
Goel, VK .
JOURNAL OF NEUROSURGERY, 1996, 84 (06) :1039-1045
[6]
Reoperation rates for acute graft extrusion and pseudarthrosis after one-level anterior corpectomy and fusion with and without plate instrumentation: Etiology and corrective management [J].
Epstein, NE .
SURGICAL NEUROLOGY, 2001, 56 (02) :73-80
[7]
A proposed technique for intraoperative measurement of cervical spine stiffness [J].
Frank, E ;
Chamberland, D ;
Ragel, B .
NEUROSURGERY, 1996, 39 (01) :147-150
[8]
Herkowitz HN, 1992, SPINE, P597
[9]
A prospective comparison of the standard and reverse Robinson cervical grafting techniques: Radiographic and clinical analyses [J].
Jenis, LG ;
An, HS ;
Simpson, JM .
JOURNAL OF SPINAL DISORDERS, 2000, 13 (05) :369-373
[10]
Effect of endplate conditions and bone mineral density on the compressive strength of the graft-endplate interface in anterior cervical spine fusion [J].
Lim, TH ;
Kwon, H ;
Jeon, CH ;
Kim, JG ;
Sokolowski, M ;
Natarajan, R ;
An, HS ;
Andersson, GBJ .
SPINE, 2001, 26 (08) :951-956