SPATIAL RESOLUTION AND NOISE PROPERTIES OF REGULARIZED MOTION-COMPENSATED IMAGE RECONSTRUCTION

被引:4
作者
Chun, Se Young [1 ]
Fessler, Jeffrey A. [1 ]
机构
[1] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
来源
2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2 | 2009年
关键词
motion-compensated image reconstruction; spatial resolution and noise properties; quadratic regularization parameter; space-invariant tomographs;
D O I
10.1109/ISBI.2009.5193189
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Reducing motion artifacts is an important problem in medical image reconstruction. Using gating to partition data into separate frames can reduce motion artifacts but can increase noise in images reconstructed from individual frames. One can pool the frames to reduce noise by using motion-compensated image reconstruction (MCIR) methods. MCIR methods have been studied in many medical imaging modalities to reduce both noise and motion artifacts. However, there has been less analysis of the spatial resolution and noise properties of MCIR methods. This paper analyzes the spatial resolution and noise properties of MCIR methods based on a general parametric motion model. For simplicity we consider the motion to be given. We present a method to choose quadratic spatial regularization parameters to provide predictable resolution properties that are independent of the object and the motion. The noise analysis shows that the estimator variance depends on both the measurement covariance and the Jacobian determinant values of the motion. A 2D PET simulation demonstrates the theoretical results.
引用
收藏
页码:863 / 866
页数:4
相关论文
共 14 条
[1]   Analysis of resolution and noise properties of nonquadratically regularized image reconstruction methods for PET [J].
Ahn, Sangtae ;
Leahy, Richard M. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (03) :413-424
[2]   Mean and covariance properties of dynamic PET reconstructions from list-mode data [J].
Asma, E ;
Leahy, RM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (01) :42-54
[3]  
Asma E, 2006, IEEE NUCL SCI CONF R, P1762
[4]  
Chun SY., 2009, P SPIE, V7258, p72580U
[5]   Mean and variance of implicitly defined biased estimators (such as penalized maximum likelihood): Applications to tomography [J].
Fessler, JA .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1996, 5 (03) :493-506
[6]   Spatial resolution properties of penalized-likelihood image reconstruction: Space-invariant tomographs [J].
Fessler, JA ;
Rogers, WL .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1996, 5 (09) :1346-1358
[7]   PENALIZED WEIGHTED LEAST-SQUARES IMAGE-RECONSTRUCTION FOR POSITRON EMISSION TOMOGRAPHY [J].
FESSLER, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (02) :290-300
[8]   Joint estimation of image and deformation parameters in motion-corrected PET [J].
Jacobson, MW ;
Fessler, JA .
2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, :3290-3294
[9]   List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations [J].
Lamare, F. ;
Carbayo, M. J. Ledesma ;
Cresson, T. ;
Kontaxakis, G. ;
Santos, A. ;
Le Rest, C. Cheze ;
Reader, A. J. ;
Visvikis, D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (17) :5187-5204
[10]   Model-based image reconstruction for four-dimensional PET [J].
Li, Tianfang ;
Thorndyke, Brian ;
Schreibmann, Eduard ;
Yang, Yong ;
Xing, Lei .
MEDICAL PHYSICS, 2006, 33 (05) :1288-1298