Patency of different arterial and venous end-to-side microanastomosis techniques in a rat model

被引:42
作者
Adams, WP [1 ]
Ansari, MS [1 ]
Hay, MT [1 ]
Tan, J [1 ]
Robinson, JB [1 ]
Friedman, RM [1 ]
Rohrich, RJ [1 ]
机构
[1] Univ Texas, SW Med Ctr, Dept Plast Surg, Dallas, TX 75235 USA
关键词
D O I
10.1097/00006534-200001000-00026
中图分类号
R61 [外科手术学];
学科分类号
摘要
Microvascular anastomotic patency is the most important factor in determining a successful outcome in free-flap transfers. End-re-end and end-to-side techniques have been shown to provide equivalent arterial patency rates in clinical and basic science studies, and end-to-side anastomoses have been used extensively in microsurgical reconstruction. Nevertheless, the affect of venotomy shape on the patency of venous end-to-side anastomoses has not been previously reported. The purpose of this study was to compare the patency rates of end-to-side anastomoses using different techniques in both arteries and veins. In total, 104 Sprague-Dawley rats were subdivided into four groups. The rats were anesthetized, and anastomosis was performed on either the femoral artery or vein on the right with the left used as control. Vesselotomy was varied between an end-to-side hole and an end-to-side slit with patency measured immediately following surgery and at 2 weeks. No significant difference in patency or histology between these techniques was demonstrated in any group. We conclude there is no difference in patency rate between the two techniques in arterial or venous vesselotomies; however, in small vessels <1.5 mm, the slit technique is technically easier, and clinical recommendations are given.
引用
收藏
页码:156 / 161
页数:6
相关论文
共 39 条
[1]
ACLAND R, 1973, SURGERY, V73, P766
[2]
Acland RD., 1980, MICROSURGERY PRACTIC
[3]
A COMPARATIVE-STUDY OF FLAP SURVIVAL RATES IN END-TO-END AND END-TO-SIDE MICRO-VASCULAR ANASTOMOSIS [J].
ALBERTENGO, JB ;
RODRIGUEZ, A ;
BUNCKE, HJ ;
HALL, EJ .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1981, 67 (02) :194-199
[4]
ARNBJORNSSON E O, 1986, Microsurgery, V7, P166, DOI 10.1002/micr.1920070408
[5]
CAN VARYING FLOW VELOCITY ACROSS AN ARTERIAL ANASTOMOSIS PREVENT THROMBOEMBOLIC INJURY [J].
BARKER, JH ;
ANDRESEN, DM ;
ANDERSON, GL ;
SCHUSCHKE, D ;
GU, JM ;
GUPTA, S ;
HJORTDAL, VE ;
DERR, JW ;
BANIS, JC ;
ACLAND, RD .
MICROSURGERY, 1995, 16 (05) :349-356
[6]
Blood-flow velocity as a factor in postoperative microvascular patency [J].
Bodor, R ;
Yoleri, L ;
Zhang, F ;
Buncke, GM ;
Lineaweaver, WC ;
Buncke, HJ .
JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 1997, 13 (07) :463-470
[7]
The use of lidocaine in microvascular reconstruction [J].
Chafin, JB ;
Wax, MK ;
Johnstone, R ;
Bishop, D .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1997, 117 (01) :93-98
[8]
COMPARISON OF 10-O POLYPROPYLENE AND 10-O NYLON SUTURES IN RAT ARTERIAL ANASTOMOSIS [J].
CHEN, LE ;
SEABER, AV ;
URBANIAK, JR .
MICROSURGERY, 1993, 14 (05) :328-333
[9]
CHEN Z, 1982, MICROSURGERY
[10]
Experience with the continuous suture microvascular anastomosis in 200 consecutive free flaps [J].
Cordeiro, PG ;
Santamaria, E .
ANNALS OF PLASTIC SURGERY, 1998, 40 (01) :1-6