ITP in dynamically double-coated fused-silica capillaries

被引:18
作者
Caslavska, Jitka [1 ]
Thormann, Wolfgang [1 ]
机构
[1] Univ Bern, Dept Clin Pharmacol, CH-3010 Bern, Switzerland
关键词
dynamic coating; electroosmosis; ionic strength; ITP; simulation;
D O I
10.1002/elps.200600346
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Bidirectional ITP in fused-silica capillaries double-coated with Polybrene and poly-(vinylsulfonate) is a robust approach for analysis of low-molecular-mass compounds. EOF towards the cathode is strong (mobility > 4.0 x 10(-8) m(2)/Vs) within the entire pH range investigated (2.40-8.08), dependent on ionic strength and buffer used and, at constant ionic strength, higher at alkaline pH. Electrokinetic separations and transport in such coated capillaries can be described with a dynamic computer model which permits the combined simulation of electrophoresis and electroosmosis in which the EOF is predicted either with a constant (i.e. pH- and ionic strength-independent) or a pH- and ionic strength-dependent electroosmotic mobility. Detector profiles predicted by computer simulation agree qualitatively well with bidirectional isotachopherograms that are monitored with a setup comprising two axial contactless conductivity detectors and a UV absorbance detector. The varying EOF predicted with a pH- and ionic strength-dependent electroosmotic mobility can be regarded as being realistic.
引用
收藏
页码:4618 / 4630
页数:13
相关论文
共 38 条
[1]   Enhanced pharmaceutical analysis by CE using dynamic surface coating system [J].
Altria, KD .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (03) :447-453
[2]  
Bendahl L, 2001, ELECTROPHORESIS, V22, P2565, DOI 10.1002/1522-2683(200107)22:12<2565::AID-ELPS2565>3.0.CO
[3]  
2-I
[4]  
Bocek P., 1988, ANAL ISOTACHOPHORESI
[5]   Dynamically coated capillaries improve the identification power of capillary zone electrophoresis for basic drugs in toxicological analysis [J].
Boone, CM ;
Jonkers, EZ ;
Franke, JP ;
de Zeeuw, RA ;
Ensing, K .
JOURNAL OF CHROMATOGRAPHY A, 2001, 927 (1-2) :203-210
[6]   Bidirectional isotachophoresis in open-tubular, untreated fused-silica capillaries [J].
Caslavska, J ;
Thormann, W .
JOURNAL OF CHROMATOGRAPHY A, 1997, 772 (1-2) :3-17
[7]   Electrophoretic separations in PMMA capillaries with uniform and discontinuous buffers [J].
Caslavska, J ;
Thormann, W .
JOURNAL OF MICROCOLUMN SEPARATIONS, 2001, 13 (02) :69-83
[8]   Noncovalently bilayer-coated capillaries for efficient and reproducible analysis of proteins by capillary electrophoresis [J].
Catai, JR ;
Tervahauta, HA ;
de Jong, GJ ;
Somsen, GW .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1083 (1-2) :185-192
[9]   Efficient and reproducible analysis of peptides by capillary electrophoresis using noncovalently bilayer-coated capillaries [J].
Catai, JR ;
Somsen, GW ;
de Jong, GJ .
ELECTROPHORESIS, 2004, 25 (06) :817-824
[10]   Capillary electrophoresis using copolymers of different composition as physical coatings:: A comparative study [J].
Erny, GL ;
Elvira, C ;
San Román, J ;
Cifuentes, A .
ELECTROPHORESIS, 2006, 27 (5-6) :1041-1049