ITP in dynamically double-coated fused-silica capillaries

被引:18
作者
Caslavska, Jitka [1 ]
Thormann, Wolfgang [1 ]
机构
[1] Univ Bern, Dept Clin Pharmacol, CH-3010 Bern, Switzerland
关键词
dynamic coating; electroosmosis; ionic strength; ITP; simulation;
D O I
10.1002/elps.200600346
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Bidirectional ITP in fused-silica capillaries double-coated with Polybrene and poly-(vinylsulfonate) is a robust approach for analysis of low-molecular-mass compounds. EOF towards the cathode is strong (mobility > 4.0 x 10(-8) m(2)/Vs) within the entire pH range investigated (2.40-8.08), dependent on ionic strength and buffer used and, at constant ionic strength, higher at alkaline pH. Electrokinetic separations and transport in such coated capillaries can be described with a dynamic computer model which permits the combined simulation of electrophoresis and electroosmosis in which the EOF is predicted either with a constant (i.e. pH- and ionic strength-independent) or a pH- and ionic strength-dependent electroosmotic mobility. Detector profiles predicted by computer simulation agree qualitatively well with bidirectional isotachopherograms that are monitored with a setup comprising two axial contactless conductivity detectors and a UV absorbance detector. The varying EOF predicted with a pH- and ionic strength-dependent electroosmotic mobility can be regarded as being realistic.
引用
收藏
页码:4618 / 4630
页数:13
相关论文
共 38 条
[11]  
EVERAERTS FM, 1976, ISOTACHOPHORESIS
[12]  
Foret F., 1993, CAPILLARY ZONE ELECT
[13]   HIGH-FREQUENCY CONTACTLESS CONDUCTIVITY DETECTION IN ISOTACHOPHORESIS [J].
GAS, B ;
DEMJANENKO, M ;
VACIK, J .
JOURNAL OF CHROMATOGRAPHY, 1980, 192 (02) :253-257
[14]  
Gas B, 2002, ELECTROPHORESIS, V23, P3520, DOI 10.1002/1522-2683(200210)23:20<3520::AID-ELPS3520>3.0.CO
[15]  
2-G
[16]  
Gas B, 2005, LC GC EUR, V18, P282
[17]   ISOTACHOPHORESIS OF PROTEINS IN UNCOATED OPEN-TUBULAR FUSED-SILICA CAPILLARIES WITH A SIMPLE APPROACH FOR COLUMN CONDITIONING [J].
GEBAUER, P ;
THORMANN, W .
JOURNAL OF CHROMATOGRAPHY, 1991, 558 (02) :423-429
[18]   Determination of pKa values by capillary zone electrophoresis with a dynamic coating procedure [J].
Geiser, L ;
Henchoz, Y ;
Galland, A ;
Carrupt, PA ;
Veuthey, JL .
JOURNAL OF SEPARATION SCIENCE, 2005, 28 (17) :2374-2380
[19]   Capillaries modified by polyelectrolyte multilayers for electrophoretic separations [J].
Graul, TW ;
Schlenoff, JB .
ANALYTICAL CHEMISTRY, 1999, 71 (18) :4007-4013
[20]  
Horvath J, 2001, ELECTROPHORESIS, V22, P644, DOI 10.1002/1522-2683(200102)22:4<644::AID-ELPS644>3.0.CO