Experimental validation of a rapid Monte Carlo based micro-CT simulator

被引:29
作者
Colijn, AP
Zbijewski, W
Sasov, A
Beekman, FJ
机构
[1] UMC Utrecht, Image Sci Inst, Dept Nucl Med, NL-3584 CG Utrecht, Netherlands
[2] UMC Utrecht, Rudolf Magnus Inst Neurosci, NL-3584 CG Utrecht, Netherlands
[3] Skyscan, B-2630 Aartselaar, Belgium
关键词
D O I
10.1088/0031-9155/49/18/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We describe a newly developed, accelerated Monte Carlo simulator of a small animal micro-CT scanner. Transmission measurements using aluminium slabs are employed to estimate the spectrum of the x-ray source. The simulator incorporating this spectrum is validated with micro-CT scans of physical water phantoms of various diameters, some containing stainless steel and Teflon rods. Good agreement is found between simulated and real data: normalized error of simulated projections, as compared to the real ones, is typically smaller than 0.05. Also the reconstructions obtained from simulated and real data are found to be similar. Thereafter, effects of scatter are studied using a voxelized software phantom representing a rat body. It is shown that the scatter fraction can reach tens of per cents in specific areas of the body and therefore scatter can significantly affect quantitative accuracy in small animal CT imaging.
引用
收藏
页码:4321 / 4333
页数:13
相关论文
共 27 条
[1]  
[Anonymous], MED PHYS
[2]  
[Anonymous], 2010, XCOM PHOTON CROSS SE
[3]  
BOONE J, 1998, MED PHYS, V15, P721
[4]   MONTE-CARLO SIMULATION OF THE SCATTERED RADIATION DISTRIBUTION IN DIAGNOSTIC-RADIOLOGY [J].
BOONE, JM ;
SEIBERT, JA .
MEDICAL PHYSICS, 1988, 15 (05) :713-720
[5]   THE VALIDITY OF MONTE-CARLO SIMULATION IN STUDIES OF SCATTERED RADIATION IN DIAGNOSTIC-RADIOLOGY [J].
CHAN, HP ;
DOI, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (02) :109-129
[6]   Accelerated simulation of cone beam X-ray scatter projections [J].
Colijn, AP ;
Beekman, FJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (05) :584-590
[7]   Effect of scattered radiation on image noise in cone beam CT [J].
Endo, M ;
Tsunoo, T ;
Nakamori, N ;
Yoshida, K .
MEDICAL PHYSICS, 2001, 28 (04) :469-474
[8]   COMPTON SCATTER EFFECTS IN CT RECONSTRUCTIONS [J].
GLOVER, GH .
MEDICAL PHYSICS, 1982, 9 (06) :860-867
[9]   METHOD FOR ESTIMATING THE INTENSITY OF SCATTERED RADIATION USING A SCATTER GENERATION MODEL [J].
HONDA, M ;
KIKUCHI, K ;
KOMATSU, KI .
MEDICAL PHYSICS, 1991, 18 (02) :219-226
[10]  
HUBBELL JH, 1979, J PHYS CHEM REF DATA, V9, P69