Three-dimensional reconstruction of the coronary artery wall by image fusion of intravascular ultrasound and bi-plane angiography

被引:36
作者
Cothren, RM
Shekhar, R
Tuzcu, EM
Nissen, SE
Cornhill, JF
Vince, DG
机构
[1] Cleveland Clin Fdn, Lerner Res Inst, Dept Biomed Engn ND20, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Dept Cardiol, Cleveland, OH 44195 USA
来源
INTERNATIONAL JOURNAL OF CARDIAC IMAGING | 2000年 / 16卷 / 02期
关键词
coronary arteries; image processing; intravascular ultrasonography;
D O I
10.1023/A:1006304419505
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Intravascular ultrasound (IVUS) is becoming increasingly accepted for assessing coronary anatomy. However, its utility in visualizing and quantifying coronary morphology has been limited by its 2D tomographic nature. This study presents a 3D reconstruction technique that accurately preserves 3D geometric information. Methods and Results: Images obtained from manual IVUS pullbacks and continuous bi-plane angiography were fused, using angiography to reconstruct the transducer trajectory and aid in solving for the correct rotational orientation. A novel 3D active surface method automatically identified the luminal and medial-adventitial borders which, when superimposed on the transducer trajectory, could be surface-rendered for visualization and morphometry. Segmentation agreed well with manual assessment, and 3D luminal shape matched that of angiography when projected to 2D. Conclusions: We conclude that this method provides an accurate reconstruction of the vessel's anatomy, which accounts for the true curvature of the vessel.
引用
收藏
页码:69 / 85
页数:17
相关论文
共 52 条
[1]  
CASTLEMAN K. R., 1996, Digital image processing
[2]   A methodology for evaluation of boundary detection algorithms on medical images [J].
Chalana, V ;
Kim, YM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (05) :642-652
[3]   A multiple active contour model for cardiac boundary detection on echocardiographic sequences [J].
Chalana, V ;
Linker, DT ;
Haynor, DR ;
Kim, YM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (03) :290-298
[4]   INVITRO VALIDATION OF 3-DIMENSIONAL INTRAVASCULAR ULTRASOUND FOR THE EVALUATION OF ARTERIAL INJURY AFTER BALLOON ANGIOPLASTY [J].
COY, KM ;
PARK, JC ;
FISHBEIN, MC ;
LAAS, T ;
DIAMOND, GA ;
ADLER, L ;
MAURER, G ;
SIEGEL, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (03) :692-700
[5]  
Di Mario C, 1992, J Am Soc Echocardiogr, V5, P135
[6]  
DIMARIO C, 1995, BRIT HEART J, V73, P26
[7]  
DUDANI SA, 1977, IEEE T COMPUT, V1, P39
[8]   Accurate three-dimensional reconstruction of intravascular ultrasound data - Spatially correct three-dimensional reconstructions [J].
Evans, JL ;
Ng, KH ;
Wiet, SG ;
Vonesh, MJ ;
Burns, WB ;
Radvany, MG ;
Kane, BJ ;
Davidson, CJ ;
Roth, SI ;
Kramer, BL ;
Meyers, SN ;
McPherson, DD .
CIRCULATION, 1996, 93 (03) :567-576
[9]  
FITZGERALD PJ, 1992, CIRCULATION S1, V86, P1
[10]  
FRIEDLAND N, 1989, COMPUTERS CARDIOLOGY