Blood glucose: Measurement in the point-of-care setting

被引:15
作者
Kiechle, FL [1 ]
Main, RI [1 ]
机构
[1] William Beaumont Hosp, Dept Clin Pathol, Royal Oak, MI 48073 USA
关键词
D O I
10.1309/4BF1-ET6T-WFE3-M7XA
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Point-of-care testing (POCT) for glucose at the bedside or in the home or hospital is used to monitor patients with diabetes-not to establish the diagnosis of diabetes mellitus, Successful POCT for glucose in the hospital requires the formation of an administrative committee with membership from all affected areas. This committee will evaluate and approve the specific device to be used, determine areas within the hospital and individuals to be trained and authorized to use the technology, and monitor the quality assurance, quality control and other records as reviewed by the POCT coordinator(s). The POCT program for glucose should be evaluated to eliminate potential preanalytical analytical, and postanalytical errors. In the future, radiofrequency or modem to the laboratory information system will directly connect POC glucose devices, moreover, noninvasive measurement techniques will eliminate the present requirement for skin puncture.
引用
收藏
页码:276 / 282
页数:7
相关论文
共 45 条
  • [21] KIECHLE FL, 1997, ADV LAB, V6, P10
  • [22] KIECHLE FL, 1998, POINT OF CARE TESTIN, P1
  • [23] Multicenter study of oxygen-insensitive handheld glucose point-of-care testing in critical care hospital ambulatory patients in the United States and Canada
    Kost, GJ
    Vu, HT
    Lee, JH
    Bourgeois, P
    Kiechle, FL
    Martin, C
    Miller, SS
    Okorodudu, AO
    Podczasy, JJ
    Webster, R
    Whitlow, KJ
    [J]. CRITICAL CARE MEDICINE, 1998, 26 (03) : 581 - 590
  • [24] Influence of blood sample oxygen tension on blood glucose concentration measured using an enzyme-electrode method
    Kurahashi, K
    Maruta, H
    Usuda, Y
    Ohtsuka, M
    [J]. CRITICAL CARE MEDICINE, 1997, 25 (02) : 231 - 235
  • [25] UTILIZATION AND COST-ANALYSIS OF BEDSIDE CAPILLARY GLUCOSE TESTING IN A LARGE TEACHING HOSPITAL - IMPLICATIONS FOR MANAGING POINT OF CARE TESTING
    LEELEWANDROWSKI, E
    LAPOSATA, M
    ESCHENBACH, K
    CAMOOSO, C
    NATHAN, DM
    GODINE, JE
    HURXTHAL, K
    GOFF, J
    LEWANDROWSKI, K
    [J]. AMERICAN JOURNAL OF MEDICINE, 1994, 97 (03) : 222 - 230
  • [26] Lum G, 1996, AM J CLIN PATHOL, V106, P390
  • [27] MacKenzie HA, 1999, CLIN CHEM, V45, P1587
  • [28] DATA MANAGEMENT PROGRAMS FOR BEDSIDE GLUCOSE TESTING
    MAIN, RI
    WRIGHT, J
    KIECHLE, FL
    [J]. LABORATORY MEDICINE, 1994, 25 (12) : 784 - 789
  • [29] Malin SF, 1999, CLIN CHEM, V45, P1651
  • [30] USE OF ARTERIAL BLOOD WITH BEDSIDE GLUCOSE REFLECTANCE METERS IN AN INTENSIVE-CARE UNIT - ARE THEY ACCURATE
    MASER, RE
    BUTLER, MA
    DECHERNEY, GS
    [J]. CRITICAL CARE MEDICINE, 1994, 22 (04) : 595 - 599