Development of an ion store time-of-flight mass spectrometer for the analysis of volatile compounds in air

被引:31
作者
Chambers, DM
Grace, LI
Andresen, BD
机构
[1] Forensic Science Center, Lawrence Livermore Natl. Laboratory, Livermore
关键词
D O I
10.1021/ac970102g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A time-of-flight mass spectrometer (TOF-MS) that incorporates an ion storage trap as a pulsed extraction source and sample preconcentrator has been developed for air monitoring, This new instrument configuration is designed for real-time monitoring of changes in trace volatile and semivolatile compound concentrations in air. Typically, detection limits are in the low parts per billion (v/v) range. This ion store/TOF-MS configuration permits. a relatively large volume air flux to be drawn directly into the ion trap cavity, creating a local pressure that exceeds 10(-4) Torr. Operating the ion trap at this pressure increases the extent of chemical ionization with the abundant N2- and O2+ that are formed by electron impact The air background also serves as a suitable collisional damping matrix, helping to compress the ion cloud to the center of the trap, which is ideal for TOF-MS analysis. Ions are typically accumulated in the trap for 400 ms, at which point they are extracted through the exit end cap and analyzed within 100 ps, thus yielding a duty cycle near 100%. The necessary hardware and electronics configuration needed to obtain optimum resolution (routinely 2000 m/Delta m, fwhm), mass accuracy and sensitivity is described.
引用
收藏
页码:3780 / 3790
页数:11
相关论文
共 60 条
[1]   THE DETERMINATION OF SUB PART-PER-BILLION LEVELS OF VOLATILE ORGANIC-COMPOUNDS IN AIR BY PRECONCENTRATION FROM SMALL SAMPLE VOLUMES [J].
ALMASI, E ;
KIRSHEN, N ;
KERN, H .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1993, 52 (1-4) :39-48
[2]  
BEREZKIN VG, 1991, GAS CHROMATOGRAPHY A
[3]   SAMPLING AND ANALYSIS OF VOLATILE ORGANIC-COMPOUNDS IN ESTUARINE AIR BY GAS-CHROMATOGRAPHY AND MASS-SPECTROMETRY [J].
BIANCHI, AP ;
VARNEY, MS .
JOURNAL OF CHROMATOGRAPHY, 1993, 643 (1-2) :11-23
[4]   LOW-PRESSURE CHEMICAL IONIZATION SOURCE - APPLICATION OF A NOVEL TYPE OF ION STORAGE MASS-SPECTROMETER [J].
BONNER, RF ;
TODD, JFJ ;
LAWSON, G .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1972, (21) :1179-&
[5]   THE EFFECTS OF AIR AND HELIUM ON THE PERFORMANCE OF THE ION-TRAP DETECTOR WHEN USED FOR REAL-TIME MONITORING OF SOME ATMOSPHERIC POLLUTANTS [J].
CAMERON, D ;
HEMBERGER, PH ;
ALARID, JE ;
LEIBMAN, CP ;
WILLIAMS, JD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (10) :774-781
[6]   ROLE OF GAS-DYNAMICS IN NEGATIVE-ION FORMATION IN AN ATMOSPHERIC SAMPLING GLOW-DISCHARGE IONIZATION SOURCE [J].
CHAMBERS, DM ;
MCLUCKEY, SA ;
GLISH, GL .
ANALYTICAL CHEMISTRY, 1993, 65 (06) :778-783
[7]   PLASMA SOURCE ATMOSPHERIC-PRESSURE IONIZATION DETECTION OF LIQUID INJECTION USING AN ION-TRAP STORAGE REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER [J].
CHIEN, BM ;
MICHAEL, SM ;
LUBMAN, DM .
ANALYTICAL CHEMISTRY, 1993, 65 (14) :1916-1924
[8]   ONLINE DETECTION OF VOLATILE ORGANIC-COMPOUNDS IN AIR AT PARTS-PER-TRILLION LEVELS BY MEMBRANE INTRODUCTION MASS-SPECTROMETRY [J].
CISPER, ME ;
GILL, CG ;
TOWNSEND, LE ;
HEMBERGER, PH .
ANALYTICAL CHEMISTRY, 1995, 67 (08) :1413-1417
[9]   ORTHOGONAL ACCELERATION - A NEW DIRECTION FOR TIME-OF-FLIGHT MASS-SPECTROMETRY - FAST, SENSITIVE MASS ANALYSIS FOR CONTINUOUS ION SOURCES [J].
COLES, J ;
GUILHAUS, M .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1993, 12 (05) :203-213
[10]   RESOLUTION LIMITATIONS FROM DETECTOR PULSE-WIDTH AND JITTER IN A LINEAR ORTHOGONAL-ACCELERATION TIME-OF-FLIGHT MASS-SPECTROMETER [J].