Spectral coronary multidetector computed tomography angiography: Dual benefit by facilitating plaque characterization and enhancing lumen depiction

被引:33
作者
Boll, Daniel T.
Hoffmann, Martin H.
Huber, Nadine
Bossert, Andrea S.
Aschoff, Andrik J.
Fleiter, Thorsten R.
机构
[1] Univ Hosp Ulm, Dept Radiol, D-89075 Ulm, Germany
[2] Univ Hosp Ulm, Dept Surg, D-89075 Ulm, Germany
[3] Univ Maryland, Univ Hosp Maryland, Dept Radiol, Baltimore, MD 21201 USA
关键词
computed tomography scanner; contrast agents; coronary vessels; CONTRAST AGENT; CT; SUBTRACTION; GADOLINIUM;
D O I
10.1097/01.rct.0000228162.70849.26
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Objective: To assess ex vivo specimens of atherosclerotic coronary arteries by dual energy (DE) multidetector computed tomography (MDCT) imaging, and to correlate depicted vessel lumen morphology and detected tissue characteristics with histopathologic analysis. Methods: Coronary arteries were imaged on a 16-slice MDCT using a DE protocol consisting of a 90- and 140-kV scan. Coronary arteries were perfused with iodine- and gadolinium-based contrast agents. The DE K-edge subtractions were performed. Regions-of-interest were placed on histopathologically/radiographically-matched vascular lumen and wall, fibromuscular and calcified plaque, and fat tissues. Vascular/tissue contrast-to-noise ratios (CNR) were calculated, and their dependence on tissue type and contrast agent type was statistically evaluated. Results: Tissue CNR analysis confirmed that all tissue types were successfully distinguished. Vascular wall and fibromuscular plaque achieved a significant increase in CNR ratios when DE techniques were used compared with 140 kV protocols. Conclusions: Spectral DE MDCT imaging of ex vivo atherosclerotic coronary arteries allows successful tissue characterization and enhances depiction of coronary lumen.
引用
收藏
页码:804 / 811
页数:8
相关论文
共 22 条
[1]
Achenbach S, 2000, CIRCULATION, V102, P2823
[2]
[Anonymous], LANCET S2
[3]
METHODS AND THEORY OF RELIABILITY [J].
BARTKO, JJ ;
CARPENTER, WT .
JOURNAL OF NERVOUS AND MENTAL DISEASE, 1976, 163 (05) :307-317
[4]
Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique [J].
Cademartiri, F ;
Nieman, K ;
van der Lugt, A ;
Raaijmakers, RH ;
Mollet, N ;
Pattynama, PMT ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2004, 233 (03) :817-823
[5]
Dilmanian F A, 1992, Am J Physiol Imaging, V7, P175
[6]
Performance of computed tomography for contrast agent concentration measurements with monochromatic x-ray beams:: comparison of K-edge versus temporal subtraction [J].
Elleaume, H ;
Charvet, AM ;
Corde, S ;
Estéve, F ;
Le Bas, JF .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (18) :3369-3385
[7]
Gadolinium as a CT contrast agent: Assessment in a porcine model [J].
Gierada, DS ;
Bae, KT .
RADIOLOGY, 1999, 210 (03) :829-834
[8]
Original report. Digital radiography with dual-energy subtraction: Improved evaluation of cardiac calcification. [J].
Gilkeson, RC ;
Novak, RD ;
Sachs, P .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (05) :1233-1238
[9]
Noninvasive coronary angiography with multislice computed tomography [J].
Hoffmann, MHK ;
Shi, HS ;
Schmitz, BL ;
Schmid, FT ;
Lieberknecht, ML ;
Schulze, R ;
Ludwig, B ;
Kroschel, U ;
Jahnke, N ;
Haerer, W ;
Brambs, HJ ;
Aschoff, AJ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (20) :2471-2478
[10]
DICHROMATIC ABSORPTION RADIOGRAPHY - DICHROMOGRAPHY [J].
JACOBSON, B .
ACTA RADIOLOGICA, 1953, 39 (06) :437-452