Microfluidic system with integrated electroosmotic pumps, concentration gradient generator and fish cell line (RTgill-W1)-towards water toxicity testing

被引:55
作者
Glawdel, Tomasz [1 ]
Elbuken, Caglar [1 ]
Lee, Lucy E. J. [2 ]
Ren, Carolyn L. [1 ]
机构
[1] Univ Waterloo, Dept Mech & Mechatron Engn, Waterloo, ON N2L 3G1, Canada
[2] Wilfrid Laurier Univ, Dept Biol, Waterloo, ON N2L 3C5, Canada
关键词
CAPILLARY-ELECTROPHORESIS; HYDROPHOBIC RECOVERY; CULTURE; TECHNOLOGIES; SULFATE; FLOW;
D O I
10.1039/b911412m
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
This study presents a microfluidic system that incorporates electroosmotic pumps, a concentration gradient generator and a fish cell line (rainbow trout gill) to perform toxicity testing on fish cells seeded in the system. The system consists of three mechanical components: (1) a toxicity testing chip containing a microfluidic gradient generator which creates a linear concentration distribution of toxicant in a cell test chamber, (2) an electroosmotic (EO) pump chip that controls the flow rate and operation of the toxicity chip, and (3) indirect reservoirs that connect the two chips allowing for the toxicant solution to be pumped separately from the electroosmotic pump solution. The flow rate and stability of the EO pumps was measured and tested by monitoring the gradient generator using fluorescence microscopy. Furthermore, a lethality test was performed with this system setup using a rainbow trout gill cell line (RTgill-W1) as the test cells and sodium dodecyl sulfate as a model toxicant. A gradient of sodium dodecyl sulfate, from 0 to 50 mu g mL(-1), was applied for 1 hr to the attached cells, and the results were quantified using a Live/Dead(TM) cell assay. This work is a preliminary study on the application of EO pumps in a living cell assay, with the potential to use the pumps in portable water quality testing devices with RTgill-W1 cells as the biosensors.
引用
收藏
页码:3243 / 3250
页数:8
相关论文
共 32 条
[1]
A Y-channel design for improving zeta potential and surface conductivity measurements using the current monitoring method [J].
Almutairi, Zeyad A. ;
Glawdel, Tomasz ;
Ren, Carolyn L. ;
Johnson, David A. .
MICROFLUIDICS AND NANOFLUIDICS, 2009, 6 (02) :241-251
[2]
Sodium lauryl sulfate and triclosan: In vitro cytotoxicity studies with gingival cells [J].
Babich, H ;
Babich, JP .
TOXICOLOGY LETTERS, 1997, 91 (03) :189-196
[4]
Long-term stable electroosmotic pump with ion exchange membranes [J].
Brask, A ;
Kutter, JP ;
Bruus, H .
LAB ON A CHIP, 2005, 5 (07) :730-738
[5]
Generation of complex concentration profiles in microchannels in a logarithmically small number of steps [J].
Campbell, Kyle ;
Groisman, Alex .
LAB ON A CHIP, 2007, 7 (02) :264-272
[6]
Human neural stem cell growth and differentiation in a gradient-generating microfluidic device [J].
Chung, BG ;
Flanagan, LA ;
Rhee, SW ;
Schwartz, PH ;
Lee, AP ;
Monuki, ES ;
Jeon, NL .
LAB ON A CHIP, 2005, 5 (04) :401-406
[7]
Curtis TM, 2009, LAB CHIP, V9, P2176, DOI [10.1039/b901314h, 10.1039/b901314b]
[8]
Extending the lifetime of the running electrolyte in capillary electrophoresis by using additional compartments for external electrolysis [J].
de Jesus, DP ;
Brito-Neto, JGA ;
Richter, EM ;
Angnes, L ;
Gutz, IGR ;
do Lago, CL .
ANALYTICAL CHEMISTRY, 2005, 77 (02) :607-614
[9]
Control and detection of chemical reactions in microfluidic systems [J].
deMello, Andrew J. .
NATURE, 2006, 442 (7101) :394-402
[10]
Dynamic single cell culture array [J].
Di Carlo, Dino ;
Wu, Liz Y. ;
Lee, Luke P. .
LAB ON A CHIP, 2006, 6 (11) :1445-1449