Visualization of Deep Veins and Detection of Deep Vein Thrombosis (DVT) With Balanced Turbo Field Echo (b-TFE) and Contrast-Enhanced T1 Fast Field Echo (CE-FFE) Using a Blood Pool Agent (BPA)

被引:31
作者
Enden, Tone [1 ,2 ,4 ]
Storas, Tryggve H. [3 ]
Negard, Anne [5 ]
Haig, Ylva [1 ]
Sandvik, Leiv [6 ]
Gjesdal, Kjell-Inge [7 ]
Sandset, Per Morten [2 ,4 ]
Klow, Nils-Einar [1 ,4 ]
机构
[1] Oslo Univ Hosp, Dept Cardiovasc Radiol, N-0407 Oslo, Norway
[2] Oslo Univ Hosp, Dept Haematol, N-0407 Oslo, Norway
[3] Oslo Univ Hosp, Dept Diagnost Phys, N-0407 Oslo, Norway
[4] Univ Oslo, Fac Med, Oslo, Norway
[5] Akershus Univ Hosp, Dept Radiol, Lorenskog, Norway
[6] Oslo Univ Hosp, Clin Res Ctr, N-0407 Oslo, Norway
[7] Sunnmore MR Klinikk, Alesund, Norway
关键词
venous thrombosis; veins; magnetic resonance imaging; contrast agents; blood pool agents; MR-ANGIOGRAPHY; VENOUS THROMBOSIS; VENOGRAPHY; PRECESSION;
D O I
10.1002/jmri.22046
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: To assess image quality, vessel visualization, preliminary diagnostic properties, and interobserver variability of a novel balanced turbo field echo (b-TFE) sequence and contrast-enhanced T1 fast field echo (CE-FFE) sequence with blood pool agent (BPA). Materials and Methods: A total of 15 healthy volunteers and six patients with ultrasound-verified proximal deep vein thrombosis (DVT) were examined from the inferior vena cava (IVC) to the proximal calf veins. Results: The great majority of deep veins were completely visualized on both sequences. In healthy volunteers the WC was completely visualized in five b-TFE and 11 CE-FFE scans. and partially in seven b-TFE and four CE-FFE scans (P = 0.008). Poorest image quality was in the pelvis. Contrast-to-noise ratio (CNR) was higher on b-TFE compared to CE-FFE, with significant difference in calf images (P = 0.036). Sensitivity was 100% for proximal DVT with both methods. Specificity was 70% (CE-FFE) and 80% (b-TFE) for proximal femoral DVT; 100% in distal femoral. Interobserver reliability was kappa 1.0 (b-TFE), 0.9 (CE-FFE) for proximal, and overall poor for distal DVT. Conclusion: Contrast-enhancement did not add valuable information in visualizing deep veins of the lower limbs compared to b-TFE, though the IVC was slightly better visualized. Diagnostic properties and interobserver reliability of both sequences were good for proximal DVT and poor for distal DVT.
引用
收藏
页码:416 / 424
页数:9
相关论文
共 21 条
[1]
MR venography with true fast imaging with steady-state precession for suspected lower-limb deep vein thrombosis [J].
Cantwell, Colin Patrick ;
Cradock, Andrea ;
Bruzzi, John ;
Fitzpatrick, Patricia ;
Eustace, Stephen ;
Murray, John G. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (11) :1763-1769
[2]
A noncontrast-enhanced pulse sequence optimized to visualize human peripheral vessels [J].
Gjesdal, Kjell-Inge ;
Storaas, Tryggve ;
Geitung, Jonn-Terje .
EUROPEAN RADIOLOGY, 2009, 19 (01) :110-120
[3]
Which diagnostic tests are most useful in a chest pain unit protocol? [J].
Goodacre S. ;
Locker T. ;
Arnold J. ;
Angelini K. ;
Morris F. .
BMC Emergency Medicine, 5 (1)
[4]
Fat-suppressed steady-state free precession imaging using phase detection [J].
Hargreaves, BA ;
Vasanawala, SS ;
Nayak, KS ;
Hu, BS ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) :210-213
[5]
Initial imaging recommendations for Wasovist angiography [J].
Hartmann, M ;
Wiethoff, AJ ;
Hentrich, HR ;
Rohrer, M .
EUROPEAN RADIOLOGY, 2006, 16 :B15-B23
[6]
Three-dimensional breathhold magnetization-prepared TrueFISP - A pilot study for magnetic resonance imaging of the coronary artery disease [J].
McCarthy, Richard M. ;
Deshpande, Vibhas S. ;
Beohar, Nirat ;
Meyers, Sheridan N. ;
Shea, Steven M. ;
Green, Jordin D. ;
Liu, Xin ;
Bi, Xiaoming ;
Pereles, F. Scott ;
Finn, John Paul ;
Davidson, Charles J. ;
Carr, James C. ;
Li, Debiao .
INVESTIGATIVE RADIOLOGY, 2007, 42 (10) :665-670
[7]
Is true FISP imaging reliable in the evaluation of venous thrombosis? [J].
Pedrosa, I ;
Morrin, M ;
Oleaga, L ;
Baptista, J ;
Rofsky, NM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (06) :1632-1640
[8]
Thoracic aortic dissection and aneurysm: Evaluation with nonenhanced true FISP MR angiography in less than 4 minutes [J].
Pereles, FS ;
McCarthy, RM ;
Baskaran, V ;
Carr, JC ;
Kapoor, V ;
Krupinski, EA ;
Finn, JP .
RADIOLOGY, 2002, 223 (01) :270-274
[9]
Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO
[10]
2-S