Nanochannels on a fused-silica microchip and liquid properties investigation by time-resolved fluorescence measurements

被引:186
作者
Hibara, A
Saito, T
Kim, HB
Tokeshi, M
Ooi, T
Nakao, M
Kitamori, T
机构
[1] Univ Tokyo, Sch English, Dept Appl Chem, Bunkyo Ku, Tokyo 1138656, Japan
[2] Kanagawa Acad Sci & Technol, Integrated Chem Project, Takatsu Ku, Kawasaki, Kanagawa 2130012, Japan
[3] Univ Tokyo, Fac Engn, Dept Engn Synth, Bunkyo Ku, Tokyo 1138656, Japan
[4] Japan Sci & Technol Corp, Precursory Res Embryon Sci & Technol, Kawaguchi, Japan
关键词
D O I
10.1021/ac025808b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have fabricated nanometer-sized channels, demonstrated a technique for the introduction of liquid into the channels, and carried out time-resolved fluorescence measurements of aqueous solutions. In this study, 330-nm- and 850-nm-sized channels were fabricated on fused-silica substrates by fast atom beam etching and hydrofluoric acid bonding methods. A liquid introduction method utilizing capillary action was demonstrated. The liquid introduction was observed under an optical microscope, and the liquid velocity during the introduction was analyzed by surface energy and macroscale hydrodynamics. The liquid velocity due to capillary action in the nanometer-sized channel seemed more than four times slower than the estimation. Then, aqueous solutions of rhodamine 6G (R6G), sulforhodamine 101 (SR101), and rhodamine B (RB) in the channels were measured by time-resolved fluorescence spectroscopy; spectra of the same solution in a 250-mum-sized channel were also measured as a reference for the macrospace. Although the fluorescence spectra in the 330-nm-, 850-nm- and 250-mum-sized channels agreed with one another, the fluorescent decays in the nanometer-sized channels were faster for R6G and SR101 and slower for RB than the respective decays in the 250-mum-sized channels. The results suggested the solutions had lower dielectric constants and higher viscosities in the nanometer-sized channels.
引用
收藏
页码:6170 / 6176
页数:7
相关论文
共 37 条
[21]   Confinement and detection of single molecules in submicrometer channels [J].
Lyon, WA ;
Nie, SM .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3400-3405
[22]  
Magde D, 1999, PHOTOCHEM PHOTOBIOL, V70, P737, DOI 10.1562/0031-8655(1999)070<0737:SDOTFL>2.3.CO
[23]  
2
[24]   MINIATURIZED TOTAL CHEMICAL-ANALYSIS SYSTEMS - A NOVEL CONCEPT FOR CHEMICAL SENSING [J].
MANZ, A ;
GRABER, N ;
WIDMER, HM .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) :244-248
[25]  
NISHIMOTO T, 1998, P MUTAS 98, P311
[26]  
RAMSEY JM, 2001, P MICR AN SYST 2001
[27]   Sub-zeptomole detection in a microfabricated glass channel by thermal-lens microscopy [J].
Sato, K ;
Kawanishi, H ;
Tokeshi, M ;
Kitamori, T ;
Sawada, T .
ANALYTICAL SCIENCES, 1999, 15 (06) :525-529
[28]   Integration of flow injection analysis and zeptomole-level detection of the Fe(II)-o-phenanthroline complex [J].
Sato, K ;
Tokeshi, M ;
Kitamori, T ;
Sawada, T .
ANALYTICAL SCIENCES, 1999, 15 (07) :641-645
[29]   INTERPRETATION OF THE UNUSUAL BEHAVIOR OF H2O AND D2O AT LOW-TEMPERATURES - TESTS OF A PERCOLATION MODEL [J].
STANLEY, HE ;
TEIXEIRA, J .
JOURNAL OF CHEMICAL PHYSICS, 1980, 73 (07) :3404-3422
[30]   Integration of a microextraction system on a glass chip:: Ion-pair solvent extraction of Fe(II) with 4,7-diphenyl-1,10-phenanthrolinedisulfonic acid and tri-n-octylmethylammonium chloride [J].
Tokeshi, M ;
Minagawa, T ;
Kitamori, T .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1711-1714