Single-breathhold 3D-TrueFISP cine cardiac imaging

被引:81
作者
Jung, BA [1 ]
Hennig, J [1 ]
Scheffler, K [1 ]
机构
[1] Univ Freiburg, Dept Diagnost Radiol, Sect Med Phys, D-79106 Freiburg, Germany
关键词
TrueFISP; cardiac cine imaging; left ventricular function; breathhold; rapid imaging; heart;
D O I
10.1002/mrm.10280
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cardiac MRI function measurements are typically based on multiple breathhold 2D sequences to acquire images of the entire heart. In the present study, the feasibility of a cine 3D TrueFISP technique in which several complete volumetric measurements may be obtained during a single breathhold is demonstrated. In contrast to 3D FLASH, the TrueFISP sequence offers an excellent contrast between the myocardium and the intraventricular cavity without the use of contrast agent. An ECG-gated 3D cine TrueFISP sequence was implemented with a repetition time of 2.4-2.8 ms, which allows imaging of the complete heart within a single breathhold throughout 20-46 heartbeats with a 3D frame rate of 8-13 volumes per cardiac cycle and a spatial resolution of about 1.5 x 3.5 x 3.5 mm(3). Breathhold volumetric cine imaging with the 3D TrueFISP technique holds promise for rapid and accurate evaluation of the cardiac regional wall motion and the calculation of cardiac volume and ejection fraction. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:921 / 925
页数:5
相关论文
共 26 条
[1]   HIGH-SPEED SPIRAL-SCAN ECHO PLANAR NMR IMAGING .1. [J].
AHN, CB ;
KIM, JH ;
CHO, ZH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (01) :2-7
[2]   Elimination of eddy current artifacts in diffusion-weighted echo-planar images: The use of bipolar gradients [J].
Alexander, AL ;
Tsuruda, JS ;
Parker, DL .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) :1016-1021
[3]  
[Anonymous], 1999, MAGNETIC RESONANCE I
[4]   CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE [J].
ATKINSON, DJ ;
EDELMAN, RR .
RADIOLOGY, 1991, 178 (02) :357-360
[5]  
Barger AV, 2000, MAGNET RESON MED, V44, P821, DOI 10.1002/1522-2594(200012)44:6<821::AID-MRM1>3.0.CO
[6]  
2-S
[7]   MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study [J].
Barkhausen, J ;
Ruehm, SG ;
Goyen, M ;
Buck, T ;
Laub, G ;
Debatin, JF .
RADIOLOGY, 2001, 219 (01) :264-269
[8]   ECHO-PLANAR MR-IMAGING [J].
EDELMAN, RR ;
WIELOPOLSKI, P ;
SCHMITT, F .
RADIOLOGY, 1994, 192 (03) :600-612
[9]   RAPID NMR IMAGING OF DYNAMIC PROCESSES USING THE FLASH TECHNIQUE [J].
FRAHM, J ;
HAASE, A ;
MATTHAEI, D .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (02) :321-327
[10]  
Glover G H, 1988, Magn Reson Annu, P299