Infrared spectrometry based 13C-octanoic acid breath test in measuring human solid gastric emptying

被引:25
作者
Chen, CP
Chen, CY
Lu, CL
Chang, FY
Lee, SD
Chu, LS
Liu, RS
Wu, HC
机构
[1] Taipei Vet Gen Hosp, Div Gastroenterol, Dept Med, Taipei 11252, Taiwan
[2] Taipei Vet Gen Hosp, Dept Nucl Med, Taipei 11252, Taiwan
[3] Natl Yang Ming Univ, Sch Med, Taipei 112, Taiwan
[4] Natl Taiwan Univ, Dept Elect Engn, Taipei 10764, Taiwan
关键词
C-13-octanoic acid breath test; gastric emptying; scintigraphy;
D O I
10.1046/j.1440-1746.2003.02901.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: Because of the convenience of non-dispersive infrared spectrometry (NDIRS), we attempted to validate the usefulness of NDIRS compared with scintigraphy in human solid gastric emptying (GE) measurement, and tried to establish the normal range of solid GE based on NDIRS. Methods: Twelve healthy volunteers (three men, nine women) were recruited for simultaneous scintigraphy and (13) C-octanoic acid breath test ((13) C-OABT) studies. Stomach half-emptying time (t(1/2) ) and lag phase (t(lag) ) were the two main GE parameters measured and correlated. The breath samples were analyzed using NDIRS every 10-15 min for a total of 6 h, while scintigraphy was taken minute by minute for the first 30 min, then hourly for 4 h. Another 32 healthy volunteers (19 men, 13 women) received only the (13) C-OABT to measure their solid GE. Results: A significant correlation for t(1/2) was found between the breath test and scintigraphy (r = 0.85, P = 0.001), while t(lag) was also positively correlated (r = 0.73, P = 0.007). The reference range of t(1/2B) based on all 44 subjects was 89.4-185.1 min (135.9 +/- 21.1 min (mean +/- SD)), while the range for t(lagB) was 37.1-117.8 min (81.9 +/- 17.4 min). No demographic characteristics were found to influence the GE parameters. Conclusions: (13) C-octanoic acid breath test determined by NDIRS is a simple, non-invasive and reliable measurement, which may provide an 'office-based' tool to detect solid GE. (C) 2003 Blackwell Publishing Asia Pty Ltd.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 29 条
[1]   [C-13]octanoic acid breath test for gastric emptying of solids: Accuracy, reproducibility, and comparison with scintigraphy [J].
Choi, MG ;
Camilleri, M ;
Burton, DD ;
Zinsmeister, AR ;
Forstrom, LA ;
Nair, KS .
GASTROENTEROLOGY, 1997, 112 (04) :1155-1162
[2]   Reproducibility and simplification of 13C-octanoic acid breath test for gastric emptying of solids [J].
Choi, MG ;
Camilleri, M ;
Burton, DD ;
Zinsmeister, AR ;
Forstrom, LA ;
Nair, KS .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 1998, 93 (01) :92-98
[3]  
Choi MG, 1997, GASTROENTEROLOGY, V112, pA712
[4]  
DATZ FL, 1987, J NUCL MED, V28, P1204
[5]   13C-octanoic acid breath test for gastric emptying measurement [J].
Delbende, B ;
Perri, F ;
Couturier, O ;
Leodolter, A ;
Mauger, P ;
Bridgi, B ;
Bizais, Y ;
des Varannes, SB ;
Andriulli, A ;
Galmiche, JP .
EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2000, 12 (01) :85-91
[6]   13C octanoic acid breath test [J].
Galmiche, JP ;
Delbende, B ;
Perri, F ;
Andriulli, A .
GUT, 1998, 43 :S28-S28
[7]   MEASUREMENT OF GASTRIC-EMPTYING RATE OF SOLIDS BY MEANS OF A CARBON-LABELED OCTANOIC-ACID BREATH TEST [J].
GHOOS, YF ;
MAES, BD ;
GEYPENS, BJ ;
MYS, G ;
HIELE, MI ;
RUTGEERTS, PJ ;
VANTRAPPEN, G .
GASTROENTEROLOGY, 1993, 104 (06) :1640-1647
[8]  
HOLT S, 1979, LANCET, V1, P636
[9]   CHANGES IN GASTRIC-EMPTYING RATES WITH AGE [J].
HOROWITZ, M ;
MADDERN, GJ ;
CHATTERTON, BE ;
COLLINS, PJ ;
HARDING, PE ;
SHEARMAN, DJC .
CLINICAL SCIENCE, 1984, 67 (02) :213-218
[10]   INFLUENCE OF GENDER AND MENOPAUSE ON GASTRIC-EMPTYING AND MOTILITY [J].
HUTSON, WR ;
ROEHRKASSE, RL ;
WALD, A .
GASTROENTEROLOGY, 1989, 96 (01) :11-17