Mobile and Fixed-Bearing (All-Polyethylene Tibial Component) Total Knee Arthroplasty Designs A Prospective Randomized Trial

被引:78
作者
Gioe, Terence J. [1 ]
Glynn, Jason [1 ]
Sembrano, Jonathan [1 ]
Suthers, Kathleen [1 ]
Santos, Edward R. G. [1 ]
Singh, Jasvinder [1 ]
机构
[1] Univ Minnesota, Sch Med, Dept Vet Affairs Med Ctr, Dept Orthopaed Surg, Minneapolis, MN 55417 USA
关键词
MATCHED-PAIR ANALYSIS; FOLLOW-UP; CONSORT STATEMENT; REPLACEMENT; OUTCOMES; PATIENT; RATIONALE; MINIMUM; SYSTEM;
D O I
10.2106/JBJS.H.01442
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: Proponents of mobile-bearing total knee arthroplasty believe that it has potential advantages over a fixed-bearing design in terms of diminished wear and improved motion and/or function, but these advantages have not been demonstrated in a randomized clinical comparison to our knowledge. We conducted a patient-blinded, prospective, randomized clinical trial to compare mobile-bearing and fixed-bearing cruciate-substituting total knee arthroplasties of the same design. Methods: Patients between the ages of sixty and eighty-five years were prospectively randomized to receive a cruciate-substituting rotating-platform design or a fixed-bearing design with an all-polyethylene tibial component. There were no significant differences in the demographic characteristics (mean age, 72.2 years; mean American Society of Anesthesiologists score, 2.7; mean body mass index, 31.8 kg/m(2)) or preoperative clinical or radiographic measures between the groups. Routine clinical and radiographic follow-up measures included the Knee Society score (KSS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and Short Form-36 (SF-36) outcome measures. Results: The results of 312 arthroplasties (136 with an all-polyethylene tibial component and 176 rotating-platform designs) in 273 patients were analyzed at a minimum of two years (mean, forty-two months) postoperatively. Although there was significant improvement in both groups, there was no significant difference between the groups with regard to the mean postoperative range of motion (110.9 degrees and 109.1 degrees, respectively; p = 0.21), the mean KSS clinical score (90.4 and 88.2 points; p = 0.168), or the mean KSS pain score (44.9 and 43.1 points; p = 0.108) at this follow-up point. There were ten revisions: seven because of infection, one because of patellar fracture, one because of instability, and one because of aseptic loosening. Conclusions: The two designs functioned equivalently at the time of early follow-up in this low-to-moderate-demand patient group. The rotating-platform design had no significant clinical advantage over the design with the all-polyethylene tibial component.
引用
收藏
页码:2104 / 2112
页数:9
相关论文
共 36 条
[1]
BELLAMY N, 1988, J RHEUMATOL, V15, P1833
[2]
A comparison of fixed-bearing and mobile-bearing total knee arthroplasty at a minimum follow-up of 4.5 years [J].
Bhan, S ;
Malhotra, R ;
Kiran, EK ;
Shukla, S ;
Bijjawara, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (10) :2290-2296
[3]
Extending the CONSORT statement to randomized trials of nonpharmacologic treatment: Explanation and elaboration [J].
Boutron, Isabelle ;
Moher, David ;
Altman, Douglas G. ;
Schulz, Kenneth F. ;
Ravaud, Philippe .
ANNALS OF INTERNAL MEDICINE, 2008, 148 (04) :295-309
[4]
Buechel FF, 2001, CLIN ORTHOP RELAT R, P41
[5]
THE NEW-JERSEY LOW-CONTACT-STRESS KNEE REPLACEMENT SYSTEM - BIOMECHANICAL RATIONALE AND REVIEW OF THE 1ST 123 CEMENTED CASES [J].
BUECHEL, FF ;
PAPPAS, MJ .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1986, 105 (04) :197-204
[6]
Cemented rotating-platform total knee replacement - A nine to twelve-year follow-up study [J].
Callaghan, JJ ;
Squire, MW ;
Goetz, DD ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (05) :705-711
[7]
Callaghan JJ, 2001, CLIN ORTHOP RELAT R, P221
[8]
Cemented rotating-platform total knee replacement - A concise follow-up, at a minimum of fifteen years, of a previous report [J].
Callaghan, JJ ;
O'Rourke, MR ;
Iossi, MF ;
Liu, SS ;
Goetz, DD ;
Vittetoe, DA ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (09) :1995-1998
[9]
Collier JP, 2002, LCS MOBILE BEARING K, P74
[10]
Radiographic assessment of the thickness lost from polyethylene tibial inserts that had been sterilized differently [J].
Collier, Matthew B. ;
Engh, C. Anderson, Jr. ;
Hatten, Kyle M. ;
Ginn, Stuart D. ;
Sheils, Todd M. ;
Engh, Gerard A. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (07) :1543-1552