A designer ormosil gel for preparation of sensitive immunosensor for carcinoembryonic antigen based on simple direct electron transfer

被引:49
作者
Tan, Fang
Yan, Feng
Ju, Huangxian [1 ]
机构
[1] Nanjing Univ, Dept Chem, Key Lab Analyt Chem Life Sci, Educ Minist China, Nanjing 210093, Peoples R China
[2] Jiangsu Inst Canc Prevent & Cure, Nanjing 210009, Peoples R China
基金
中国国家自然科学基金;
关键词
ormosil; sol-gel; carcinoembryonic antigen; immunosensor; horseradish peroxidase; graphite electrode;
D O I
10.1016/j.elecom.2006.08.026
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The excellent direct electron transfer (DET) of enzyme labeled to antibody immobilized in designer organically modified silicate (ormosil) sol-gel was achieved at an electrode, which was used to construct a novel reagentless immunosensor for antigen determination. The synthesized ormosil architecture provided a hydrophilic interface for retaining the activity of immobilized enzyme labeled immunocomponent. The proposed immunosensor for carcinoembryonic antigen (CEA) prepared by immobilizing horseradish peroxidase-labeled CEA antibody (HRP-anti-CEA) in the architecture showed a surface-controlled electrode process attributed to the DET between electrode and HRP with a rate constant of 5.94 +/- 0.40 s(-1). The formation of immunocomplex upon incubation in CEA or sample solution led to block of DET and linearly decrease in voltammetric response over CEA concentration ranging from 0.5 to 3.0 and 3.0 to 120 ng ml(-1). The limit of detection for CEA was 0.4 ng ml(-1). The immunosensor showed good accuracy and acceptable storage stability, precision and reproducibility. The proposed method was simple, low-cost and potentially attractive for clinical immunoassays. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1835 / 1839
页数:5
相关论文
共 18 条
[1]   Reagentless amperometric immunosensor for human chorionic gonadotrophin based on direct electrochemistry of horseradish peroxidase [J].
Chen, J ;
Yan, F ;
Dai, Z ;
Ju, HX .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (02) :330-336
[2]   Impedance immunosensor based on receptor protein adsorbed directly on porous gold film [J].
Chen, ZP ;
Jiang, JH ;
Shen, GL ;
Yu, RQ .
ANALYTICA CHIMICA ACTA, 2005, 553 (1-2) :190-195
[3]   Serum anti-p53 antibodies in lung cancer: comparison with established tumor markers [J].
Cioffi, M ;
Vietri, MT ;
Gazzerro, P ;
Magnetta, R ;
D'Auria, A ;
Durante, A ;
Nola, E ;
Puca, GA ;
Molinari, AM .
LUNG CANCER, 2001, 33 (2-3) :163-169
[4]   Novel amperometric immunosensor for rapid separation-free immunoassay of carcinoembryonic antigen [J].
Dai, Z ;
Yan, F ;
Hua, Y ;
Hu, XY ;
Ju, HX .
JOURNAL OF IMMUNOLOGICAL METHODS, 2004, 287 (1-2) :13-20
[5]   Reagentless amperometric immunosensors based on direct electrochemistry of horseradish peroxidase for determination of carcinoma antigen-125 [J].
Dai, Z ;
Yan, F ;
Chen, J ;
Ju, HX .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5429-5434
[6]   Evaluation of the analytical performance of the Boehringer Mannheim Elecsys® 2010 immunoanalyzer [J].
Forest, JC ;
Massé, J ;
Lane, A .
CLINICAL BIOCHEMISTRY, 1998, 31 (02) :81-88
[7]   Stable sol-gel microstructured and microfluidic networks for protein patterning [J].
Kim, YD ;
Park, CB ;
Clark, DS .
BIOTECHNOLOGY AND BIOENGINEERING, 2001, 73 (05) :331-337
[8]   GENERAL EXPRESSION OF THE LINEAR POTENTIAL SWEEP VOLTAMMOGRAM IN THE CASE OF DIFFUSIONLESS ELECTROCHEMICAL SYSTEMS [J].
LAVIRON, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1979, 101 (01) :19-28
[9]   Construction of electrochemical flow immunoassay system using capillary columns and ferrocene conjugated immunoglobulin G for detection of human chorionic gonadotrophin [J].
Lim, TK ;
Matsunaga, T .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) :1063-1069
[10]   Electroanalytical determination of carcinoembryonic antigen at a silica nanoparticles/titania sol-gel composite membrane-modiried gold electrode [J].
Liu, Yan ;
Jiang, Hong .
ELECTROANALYSIS, 2006, 18 (10) :1007-1013