In situ synchrotron computed laminography of damage in carbon fibre-epoxy [90/0]s laminates

被引:69
作者
Moffat, A. J. [1 ]
Wright, P. [1 ]
Helfen, L. [2 ]
Baumbach, T. [2 ]
Johnson, G. [3 ,4 ]
Spearing, S. M. [1 ]
Sinclair, I. [1 ]
机构
[1] Univ Southampton, Sch Engn Sci, Southampton SO9 5NH, Hants, England
[2] Forschungszentrum Karlsruhe, ANKA Inst Synchrotron Radiat, Karlsruhe, Germany
[3] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[4] Univ Manchester, Sch Mat, Manchester M13 9PL, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
Composites; Fracture; Synchrotron radiation; Computed laminography; X-RAY MICROTOMOGRAPHY; CRACK-PROPAGATION; PREDICTION;
D O I
10.1016/j.scriptamat.2009.09.027
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
X-ray computed laminography (CL) with synchrotron radiation is used to investigate fracture in carbon fibre-epoxy laminates. CL allows for high-resolution (similar to 1 mu m) imaging of laterally extended objects. Whilst artefacts inherent to CL data reduce image quality compared with computed tomography (CT), imaging regions of interest in large planar samples greatly increases the engineering applicability. High-resolution in situ three-dimensional analysis of structural failure is therefore achievable at levels that would be impossible via CT or any other volume-imaging methods. (C) 2009 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:97 / 100
页数:4
相关论文
共 24 条
[1]   A study of fracture of unidirectional composites using in situ high-resolution synchrotron X-ray microtomography [J].
Aroush, D. Raz-Ben ;
Maire, E. ;
Gauthier, C. ;
Youssef, S. ;
Cloetens, P. ;
Wagner, H. D. .
COMPOSITES SCIENCE AND TECHNOLOGY, 2006, 66 (10) :1348-1353
[2]   Observation of microstructure and damage in materials by phase sensitive radiography and tomography [J].
Cloetens, P ;
PateyronSalome, M ;
Buffiere, JY ;
Peix, G ;
Baruchel, J ;
Peyrin, F ;
Schlenker, M .
JOURNAL OF APPLIED PHYSICS, 1997, 81 (09) :5878-5886
[3]   Digital x-ray tomosynthesis: current state of the art and clinical potential [J].
Dobbins, JT ;
Godfrey, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19) :R65-R106
[4]   Fatigue crack propagation:: In situ visualization using X-ray microtomography and 3D simulation using the extended finite element method [J].
Ferrié, E ;
Buffière, JY ;
Ludwig, W ;
Gravouil, A ;
Edwards, L .
ACTA MATERIALIA, 2006, 54 (04) :1111-1122
[5]   Multiscale modeling for the prediction of casting defects in investment cast aluminum alloys [J].
Hamilton, RW ;
See, D ;
Butler, S ;
Lee, PD .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2003, 343 (1-2) :290-300
[6]   High-resolution three-dimensional imaging of flat objects by synchrotron-radiation computed laminography -: art. no. 071915 [J].
Helfen, L ;
Baumbach, T ;
Mikulík, P ;
Kiel, D ;
Pernot, P ;
Cloetens, P ;
Baruchel, J .
APPLIED PHYSICS LETTERS, 2005, 86 (07) :1-3
[7]   Investigation of hybrid pixel detector arrays by synchrotron-radiation imaging [J].
Helfen, L. ;
Myagotin, A. ;
Pernot, P. ;
DiMichiel, M. ;
Mikulik, P. ;
Berthold, A. ;
Baumbach, T. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01) :163-166
[8]   Phase-contrast and holographic computed laminography [J].
Helfen, L. ;
Baumbach, T. ;
Cloetens, P. ;
Baruchel, J. .
APPLIED PHYSICS LETTERS, 2009, 94 (10)
[9]   Synchrotron-radiation computed laminography for high-resolution three-dimensional imaging of flat devices [J].
Helfen, Lukas ;
Myagotin, Anton ;
Rack, Alexander ;
Pernot, Petra ;
Mikulik, Petr ;
Di Michiel, Marco ;
Baumbach, Tilo .
PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2007, 204 (08) :2760-2765
[10]  
Kak A.C. Slaney M., 1999, PRINCIPLES COMPUTERI