Protein-binding high-performance frontal analysis of (R)- and (S)-warfarin on HSA with and without phenylbutazone

被引:25
作者
He, JY [1 ]
Shibukawa, A [1 ]
Tokunaga, S [1 ]
Nakagawa, T [1 ]
机构
[1] KYOTO UNIV,FAC PHARMACEUT SCI,SAKYO KU,KYOTO 60601,JAPAN
关键词
D O I
10.1021/js9600134
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Applicability of high-performance frontal analysis (HPFA) to the stereoselective study of drug-drug interaction upon plasma protein binding has been investigated. Racemic warfarin and phenylbutazone were used as model drugs. An on-line HPFA/HPLC system consisting of a HPFA column (diol-silica column), an extraction column, and a chiral separation column was developed, and human serum albumin solution containing racemic warfarin and/or phenylbutazone was injected directly to the HPFA column, When the injection volume das large enough, the binding equilibrium in the sample solution was reproduced in the column, and consequently a plateau region appeared on the chromatogram. This plateau region contains unbound drug(s). A given volume of eluent in the plateau part was transferred into the extraction column by column-switching. The concentrated drug(s) was then transferred to the chiral separation column to determine the unbound concentrations of the enantiomers and/or the competitor. The results agreed with those obtained by a conventional ultrafiltration-HPLC method. The influence of phenylbutazone upon the protein binding of warfarin is enantioselective. in warfarin and human serum albumin mixed solution, the unbound concentration of (R)-warfarin was 1.22 times higher than that of the S-isomer. By addition of phenylbutazone, the unbound concentration of (S)-warfarin increased more than that of (R)-warfarin, resulting in the reversed enantioselectivity, i.e., the unbound concentration of (S)-warfarin became 1.19 times larger than that of(R)-warfarin. The present method was also applicable to human plasma samples.
引用
收藏
页码:120 / 125
页数:6
相关论文
共 40 条
[31]   DETERMINATION OF THE UNBOUND CONCENTRATION OF HYDROPHOBIC DRUGS IN ALBUMIN SOLUTIONS BY HIGH-PERFORMANCE FRONTAL ANALYSIS USING A DIOL-SILICA COLUMN [J].
SHIBUKAWA, A ;
NAKAO, C ;
SAWADA, T ;
TERAKITA, A ;
MOROKOSHI, N ;
NAKAGAWA, T .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1994, 83 (06) :868-873
[32]  
SUDLOW G, 1976, MOL PHARMACOL, V12, P1052
[33]  
SUDLOW G, 1975, MOL PHARMACOL, V11, P824
[34]   ENHANCED ALBUMIN PROTEIN SEPARATIONS AND PROTEIN DRUG-BINDING CONSTANT MEASUREMENTS USING ANTIINFLAMMATORY DRUGS AS RUN BUFFER ADDITIVES IN AFFINITY CAPILLARY ELECTROPHORESIS [J].
SUN, P ;
HOOPS, A ;
HARTWICK, RA .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1994, 661 (02) :335-340
[35]   USE OF A SMALL-BORE INTERNAL-SURFACE REVERSED-PHASE SILICA COLUMN FOR THE MICRO HIGH-PERFORMANCE FRONTAL ANALYSIS OF CARBAMAZEPINE IN AN ALBUMIN SOLUTION WITH A SMALL SAMPLE VOLUME [J].
TERAKITA, A ;
SHIBUKAWA, A ;
NAKAO, C ;
NAKAGAWA, T .
ANALYTICAL SCIENCES, 1994, 10 (01) :11-15
[36]   MICRO HIGH-PERFORMANCE FRONTAL ANALYSIS FOR SIMULTANEOUS DETERMINATION OF UNBOUND AND TOTAL CARBAMAZEPINE CONCENTRATIONS IN PROTEIN-BINDING EQUILIBRIUM [J].
TERAKITA, A ;
SHIBUKAWA, A ;
NAKAGAWA, T .
ANALYTICAL SCIENCES, 1993, 9 (02) :229-232
[37]   ENANTIOMER SPECIFIC PHARMACOKINETICS [J].
TUCKER, GT ;
LENNARD, MS .
PHARMACOLOGY & THERAPEUTICS, 1990, 45 (03) :309-329
[38]   BINDING OF DRUGS BY ALBUMIN AND PLASMA-PROTEIN [J].
VALLNER, JJ .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1977, 66 (04) :447-465
[40]  
YAKOBI A, 1977, J PHARMACOKINET BIOP, V5, P123