Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules

被引:88
作者
Karabulut, N
Törü, M
Gelebek, V
Gülsün, M
Ariyurek, OM
机构
[1] Hacettepe Univ, Med Ctr, Dept Radiol, TR-06100 Ankara, Turkey
[2] Pamukkale Univ, Med Ctr, Dept Radiol, TR-20010 Denizli, Turkey
关键词
lung; nodule; neoplasms; CT;
D O I
10.1007/s00330-002-1368-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to investigate the diagnostic accuracy of low-dose helical computed tomography by comparing the number of nodules detected at low- and standard-dose CT. The prospective study included 25 patients who were referred to CT scan for the assessment of pulmonary metastases. All patients underwent CT examinations at both standard- (200 mA, 120 kV, collimation 5 mm, table feed 10 mm per rotation) and low-dose (50 mA, 120 kV, collimation 5 mm, table feed 10 mm per rotation), The number of nodules detected at each protocol was recorded. The size of the nodules was measured electronically and categorized as <3, 3-4.9, 5-6.9, 7-9.9, and greater than or equal to10 mm. Finally, the nodules detected at only standard- or low-dose CT were assessed for the underlying causes of discrepancy. In 25 patients, 533 nodules were detected at standard-dose, whereas 518 nodules were observed at low-dose CT. There were no statistically significant differences in the number of nodules detected at standard- or low-dose CT (p>0.05). Four hundred ninety-one (87.7%) nodules were detected at both standard- or low-dose CT, 42 (7.5%) nodules were observed only at standard-dose CT, and 27 (4.8%) nodules were seen only at low-dose CT. The sensitivity of low-dose CT was 92.5% for all nodules, 88.1% for nodules <5 mm, and 97.4% for nodules 2:5 mm. No significant image artifact interfering with nodule detection was observed at low-dose CT. The low-dose CT protocol used in this study provided images of adequate quality; thus, it can be used reliably in the detection or exclusion of pulmonary nodules.
引用
收藏
页码:2764 / 2769
页数:6
相关论文
共 21 条
  • [1] FEASIBILITY OF HIGH-RESOLUTION, LOW-DOSE CHEST CT IN EVALUATING THE PEDIATRIC CHEST
    AMBROSINO, MM
    GENIESER, NB
    ROCHE, KJ
    KAUL, A
    LAWRENCE, RM
    [J]. PEDIATRIC RADIOLOGY, 1994, 24 (01) : 6 - 10
  • [2] Pulmonary nodules: Experimental and clinical studies at low-dose CT
    Diederich, S
    Lenzen, H
    Windmann, R
    Puskas, Z
    Yelbuz, TM
    Henneken, S
    Klaiber, T
    Eameri, M
    Roos, N
    Peters, PE
    [J]. RADIOLOGY, 1999, 213 (01) : 289 - 298
  • [3] MATCHMAKING AND MCNEMAR IN THE COMPARISON OF DIAGNOSTIC MODALITIES
    DWYER, AJ
    [J]. RADIOLOGY, 1991, 178 (02) : 328 - 330
  • [4] A COMPARISON OF RADIATION-DOSES TO THE BREAST IN COMPUTED TOMOGRAPHIC CHEST EXAMINATIONS FOR 2 SCANNING PROTOCOLS
    EVANS, SH
    DAVIS, R
    COOKE, J
    ANDERSON, W
    [J]. CLINICAL RADIOLOGY, 1989, 40 (01) : 45 - 46
  • [5] Pulmonary nodules: detection with low-dose vs conventional-dose spiral CT
    Gartenschlager, M
    Schweden, F
    Gast, K
    Westermeier, T
    Kauczor, HU
    von Zitzewitz, H
    Thelen, M
    [J]. EUROPEAN RADIOLOGY, 1998, 8 (04) : 609 - 614
  • [6] Radiation exposure in spiral computed tomography -: Dose distribution and dose reduction
    Hidajat, N
    Mäurer, J
    Schröder, RJ
    Wolf, M
    Vogl, T
    Felix, R
    [J]. INVESTIGATIVE RADIOLOGY, 1999, 34 (01) : 51 - 57
  • [7] Low-dose, volumetric helical CT - Image quality, radiation dose, and usefulness for evaluation of bronchiectasis
    Jung, KJ
    Lee, KS
    Kim, SY
    Kim, TS
    Pyeun, YS
    Lee, JY
    [J]. INVESTIGATIVE RADIOLOGY, 2000, 35 (09) : 557 - 563
  • [8] Peripheral lung cancer: Screening and detection with low-dose spiral CT versus radiography
    Kaneko, M
    Eguchi, K
    Ohmatsu, H
    Kakinuma, R
    Naruke, T
    Suemasu, K
    Moriyama, N
    [J]. RADIOLOGY, 1996, 201 (03) : 798 - 802
  • [9] Effective doses to members of the public from the diagnostic application of ionizing radiation in Germany
    Kaul, A
    Bauer, B
    Bernhardt, J
    Nosske, D
    Veit, R
    [J]. EUROPEAN RADIOLOGY, 1997, 7 (07) : 1127 - 1132
  • [10] CHRONIC INFILTRATIVE LUNG-DISEASE - COMPARISON OF DIAGNOSTIC ACCURACIES OF RADIOGRAPHY AND LOW-AND CONVENTIONAL-DOSE THIN-SECTION CT
    LEE, KS
    PRIMACK, SL
    STAPLES, CA
    MAYO, JR
    ALDRICH, JE
    MULLER, NL
    [J]. RADIOLOGY, 1994, 191 (03) : 669 - 673