Full body virtual autopsies using a state-of-the-art volume rendering pipeline

被引:50
作者
Ljung, Patric
Winskog, Calle [1 ]
Persson, Anders
Lundstrom, Claes
Ynnerman, Anders
机构
[1] Linkoping Univ, Div Visual Informat Technol & Applicat, Linkoping, Sweden
[2] Natl Board Forens Med, Dept Forens Med, Linkoping, Sweden
[3] Linkoping Univ, Ctr Med Image Sci & Visualizat, Linkoping, Sweden
关键词
forensics; autopsies; medical visualization; volume rendering; large scale data;
D O I
10.1109/TVCG.2006.146
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
This paper presents a procedure for virtual autopsies based on interactive 3D visualizations of large scale, high resolution data from CT-scans of human cadavers. The procedure is described using examples from forensic medicine and the added value and future potential of virtual autopsies is shown from a medical and forensic perspective. Based on the technical demands of the procedure state-of-the-art volume rendering techniques are applied and refined to enable real-time, full body virtual autopsies involving gigabyte sized data on standard GPUs. The techniques applied include transfer function based data reduction using level-of-detail selection and multi-resolution rendering techniques. The paper also describes a data management component for large, out-of-core data sets and an extension to the GPU-based raycaster for efficient dual TF rendering. Detailed benchmarks of the pipeline are presented using data sets from forensic cases.
引用
收藏
页码:869 / 876
页数:8
相关论文
共 33 条
[1]  
[Anonymous], 2000, ECIS 2000 P
[2]   3D RGB image compression for interactive applications [J].
Bajaj, C ;
Ihm, I ;
Park, S .
ACM TRANSACTIONS ON GRAPHICS, 2001, 20 (01) :10-38
[3]   Multiresolution volume visualization with a texture-based octree [J].
Boada, I ;
Navazo, I ;
Scopigno, R .
VISUAL COMPUTER, 2001, 17 (03) :185-197
[4]  
Cabral B, 1994, VVS 94, P91, DOI DOI 10.1145/197938.197972
[5]   UTILITY OF POSTMORTEM COMPUTED-TOMOGRAPHY IN TRAUMA VICTIMS [J].
DONCHIN, Y ;
RIVKIND, AI ;
BARZIV, J ;
HISS, J ;
ALMOG, J ;
DRESCHER, M .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1994, 37 (04) :552-556
[6]  
ETLIK O, 2004, EUROPEAN J GEN MED, V1, P48
[7]  
FISCHMAN SL, 1997, J FORENSIC SCI, V31, P145
[8]   New technical developments in multislice CT - Part 1: Approaching isotropic resolution with sub-millimeter 16-slice scanning [J].
Flohr, T ;
Stierstorfer, K ;
Bruder, H ;
Simon, J ;
Schaller, S .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (07) :839-845
[9]  
Gao JZ, 2005, IEEE VISUALIZATION 2005, PROCEEDINGS, P183
[10]   Visibility culling using plenoptic opacity functions for large volume visualization [J].
Gao, JZ ;
Huang, J ;
Shen, HW ;
Kohl, JA .
IEEE VISUALIZATION 2003, PROCEEDINGS, 2003, :341-348