摘要
The use of a miniaturised planar separation device with integrated conductivity detection for performing bidirectional isotachophoresis (ITP) is described. The chips were produced in poly( methyl methacrylate) (PMMA) using a milling procedure. To enable bidirectional ITP the devices were designed to inject samples into the centre of the separation channel and incorporated two integrated on-column conductivity detectors, positioned at opposite ends of this channel. When used with a hydrodynamic sample transport system the devices were used for the analysis of a range of small ions: NH4+; Na+; Mg2+; Ca2+; Li+; NO3-; ClO4-; SO41; F-. Results successfully achieved included the simultaneous separation of three anions and three cations.
引用
收藏
页码:1413 / 1419
页数:7
相关论文
共 42 条
[1]  
Alarie JP, 2001, ELECTROPHORESIS, V22, P312, DOI 10.1002/1522-2683(200101)22:2<312::AID-ELPS312>3.0.CO
[2]  
2-3
[3]  
[Anonymous], P MICR TAS 98 BANFF
[4]  
Bocek P., 1988, ANAL ISOTACHOPHORESI
[5]   Isotachophoresis and isotachophoresis -: zone electrophoresis separations of inorganic anions present in water samples on a planar chip with column-coupling separation channels and conductivity detection [J].
Bodor, R ;
Madajová, V ;
Kaniansky, D ;
Masár, M ;
Jöhnck, M ;
Stanislawski, B .
JOURNAL OF CHROMATOGRAPHY A, 2001, 916 (1-2) :155-165
[6]   Bidirectional isotachophoresis in open-tubular, untreated fused-silica capillaries [J].
Caslavska, J ;
Thormann, W .
JOURNAL OF CHROMATOGRAPHY A, 1997, 772 (1-2) :3-17
[7]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[8]   ON THE MEASUREMENTS OF ELECTROPHORETIC MOBILITIES BY MEANS OF CAPILLARY ISOTACHOPHORESIS AT A CONSTANT VOLTAGE [J].
ERMAKOV, SV ;
ZHUKOV, MY ;
CAPELLI, L ;
RIGHETTI, PG .
ELECTROPHORESIS, 1995, 16 (11) :2149-2158
[9]   Micromoulded polymer electrokinetic separation systems with variable volume sampling and integrated optical and conductivity detection. [J].
Fielden, PR ;
Baldock, SJ ;
Goddard, NJ ;
Morrison, L ;
Prest, JE ;
Brown, BJT ;
Zgraggen, M .
BIOMEDICAL NANOTECHNOLOGY ARCHITECTURES AND APPLICATIONS, 2002, 4626 :429-440
[10]  
Ford SM, 1998, J MICROCOLUMN SEP, V10, P413, DOI 10.1002/(SICI)1520-667X(1998)10:5<413::AID-MCS4>3.0.CO