Recent results on chemical-vapor-deposited diamond microstrip detectors

被引:3
作者
Bauer, C
Baumann, I
Colledani, C
Conway, J
Delpierre, P
Djama, F
Dulinski, W
Fallou, A
Gan, KK
Gilmore, RS
Grigoriev, E
Hallewell, G
Han, S
Hessing, T
Hubec, J
Husson, D
Kagan, H
Kania, D
Kass, R
Kinnison, W
Knopfle, KT
Krammer, M
Llewellyn, TJ
Manfredi, PF
Pan, LS
Pernegger, H
Pernicka, M
Re, V
Roe, S
Rudge, A
Schaeffer, M
Schnetzer, S
Somalwar, S
Speziali, V
Stone, R
Trapper, RJ
Tesarek, R
Trischuk, W
Turchetta, R
Thomson, GB
Wagner, R
Weilhammer, P
White, C
Ziock, H
Zoeller, MM
机构
[1] LOS ALAMOS NATL LAB,LOS ALAMOS,NM 87545
[2] MPI HEIDELBERG,D-69029 HEIDELBERG,GERMANY
[3] CTR RECH NUCL,LEPSI,F-67037 STRASBOURG,FRANCE
[4] RUTGERS STATE UNIV,PISCATAWAY,NJ 08854
[5] CPPM,F-13288 MARSEILLE,FRANCE
[6] OHIO STATE UNIV,COLUMBUS,OH 43210
[7] UNIV BRISTOL,BRISTOL BS8 1TL,AVON,ENGLAND
[8] CERN,EUROPEAN LAB PARTICLE PHYS,CH-1211 GENEVA,SWITZERLAND
[9] AUSTRIAN ACAD SCI,A-1050 VIENNA,AUSTRIA
[10] LAWRENCE LIVERMORE NATL LAB,LIVERMORE,CA 94550
[11] UNIV PAVIA,DIPARTIMENTO ELETTR,I-27100 PAVIA,ITALY
[12] SANDIA NATL LABS,LIVERMORE,CA 94552
关键词
D O I
10.1016/S0168-9002(96)00376-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Diamond is a nearly ideal material for detecting ionizing radiation. Its outstanding radiation hardness, fast charge collection, and low leakage current allow a diamond detector to be used in high-radiation high-temperature and aggressive chemical environments. We report here the results of recent beam tests of chemical-vapor-deposited diamond microstrip detectors in a 100 GeV pion beam at CERN, Geneva, Switzerland. Using detectors with a 50 mu m strip pitch and a 50% coverage, we achieved an average signal size of 4350 electrons with a signal-to-noise ratio of 30:1 and a spatial resolution of 14.3 mu m.
引用
收藏
页码:183 / 185
页数:3
相关论文
共 11 条
[1]   CMOS LOW-NOISE MONOLITHIC FRONTENDS FOR SI STRIP DETECTOR READOUT [J].
ASPELL, P ;
BOULTER, R ;
CZERMAK, A ;
JALOCHA, P ;
JARRON, P ;
KJENSMO, A ;
LANGE, W ;
NYGARD, E ;
RUDGE, A ;
TOKER, O ;
TURALA, M ;
VONDERLIPPE, H ;
WALZ, U ;
WEILHAMMER, P ;
YOSHIOKA, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 315 (1-3) :425-429
[2]  
BAUER C, PION IRRADIATION STU
[3]  
BAUER C, UNPUB PROTON IRRADIA
[4]   FIRST MEASUREMENTS WITH A DIAMOND MICROSTRIP DETECTOR [J].
BORCHELT, F ;
DULINSKI, W ;
GAN, KK ;
HAN, S ;
HASSARD, J ;
HOWARD, A ;
KAGAN, H ;
KANIA, DR ;
KASS, R ;
LU, G ;
NYGARD, E ;
PAN, LS ;
SCHNETZER, S ;
STONE, R ;
STRAVER, J ;
TESAREK, RJ ;
TRISCHUK, W ;
WEILHAMMER, P ;
WHITE, C ;
WOODIN, RL ;
ZHAO, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 354 (2-3) :318-327
[5]  
DULINSKI W, 1995, NUCL INSTRUM METH A, V367, P202
[6]   THE EFFECT OF SURFACE-TREATMENT ON THE ELECTRICAL-PROPERTIES OF METAL CONTACTS TO BORON-DOPED HOMOEPITAXIAL DIAMOND FILM [J].
GROT, SA ;
GILDENBLAT, GS ;
HATFIELD, CW ;
WRONSKI, CR ;
BADZIAN, AR ;
BADZIAN, T ;
MESSIER, R .
IEEE ELECTRON DEVICE LETTERS, 1990, 11 (02) :100-102
[7]   RECTIFICATION AND INTERNAL PHOTOEMISSION IN METAL CVD DIAMOND AND METAL CVD DIAMOND/SILICON STRUCTURES [J].
GROT, SA ;
LEE, S ;
GILDENBLAT, GS ;
HATFIELD, CW ;
WRONSKI, CR ;
BADZIAN, AR ;
BADZIAN, T ;
MESSIER, R .
JOURNAL OF MATERIALS RESEARCH, 1990, 5 (11) :2497-2501
[8]   PROPERTIES OF METAL DIAMOND INTERFACES AND EFFECTS OF OXYGEN ADSORBED ONTO DIAMOND SURFACE [J].
MORI, Y ;
KAWARADA, H ;
HIRAKI, A .
APPLIED PHYSICS LETTERS, 1991, 58 (09) :940-941
[9]  
PAN LS, 1992, DIAMOND FILM TECHNOL, V2, P99
[10]  
PERNEGGER H, 1995, NUCL INSTRUM METH A, V367, P207