Determination of haloethers in water with dynamic hollow fiber liquid-phase microextraction using GC-FID and GC-ECD

被引:28
作者
Chiang, Jing-Shan [1 ]
Huang, Shang-Da [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Chem, Hsinchu 30043, Taiwan
关键词
haloether; liquid-phase microextraction; gas chromatography;
D O I
10.1016/j.talanta.2006.05.065
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dynamic hollow fiber liquid-phase microextraction (HF-LPME) coupled with gas chromatography with flame ionization detection (GC-FID) and GC-electron capture detecion (GC-ECD) was used for quantification of toxic haloethers in lake water. The analytes were extracted from 5 ml of aqueous sample using 4 mu l of organic solvent through a porous polypropylene hollow fiber. The effects on extraction performance of solvent selection, agitation rate, extraction time, extraction temperature, concentration of salt added and volumes of solvent for extraction and injection were optimized. The proposed method provided a good average enrichment factor of up to 231-fold, reasonable reproducibility ranging from 9 to 12% (n = 3), and good linearity (R-2 >= 0.9973) for spiked water samples. Method detection limits (MDLs) ranged from 0.55 to 4.30 mu g/l for FID and 0.11-0.34 mu g/l for ECD (n = 7). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:882 / 886
页数:5
相关论文
共 16 条
[1]   OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION CONDITIONS FOR DETERMINATION OF PHENOLS [J].
BUCHHOLZ, KD ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :160-167
[2]   USE OF BONDED PHASE SILICA SORBENTS FOR THE SAMPLING OF PRIORITY POLLUTANTS IN WASTEWATERS [J].
CHLADEK, E ;
MARANO, RS .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1984, 22 (08) :313-320
[3]  
Fawell J.K., 1988, ENV TOXICOLOGY ORGAN
[4]   Liquid phase microextraction in a single drop of organic solvent by using a conventional microsyringe [J].
He, Y ;
Lee, HK .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4634-4640
[5]   Determination of haloethers in water by solid-phase microextraction [J].
Huang, SD ;
Ting, CY ;
Lin, CS .
JOURNAL OF CHROMATOGRAPHY A, 1997, 769 (02) :239-246
[6]  
LICHTENBERG JJ, 1987, ORGANIC POLLUTANTS W, P70
[7]   Application of single-drop microextraction and comparison with solid-phase microextraction and solid-phase extraction for the determination of α- and β-endosulfan in water samples by gas chromatography-electron-capture detection [J].
López-Blanco, MC ;
Blanco-Cid, S ;
Cancho-Grande, B ;
Simal-Gándara, J .
JOURNAL OF CHROMATOGRAPHY A, 2003, 984 (02) :245-252
[8]  
Montgomery JH, 1990, GROUNDWATER CHEM DES
[9]   Application of single drop microextraction for analysis of chemical warfare agents and related compounds in water by gas chromatography/mass spectrometry [J].
Palit, M ;
Pardasani, D ;
Gupta, AK ;
Dubey, DK .
ANALYTICAL CHEMISTRY, 2005, 77 (02) :711-717
[10]   Liquid-liquid-liquid microextraction for sample preparation of biological fluids prior to capillary electrophoresis [J].
Pedersen-Bjergaard, S ;
Rasmussen, KE .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2650-2656