Exact and approximate rebinning algorithms for 3-D PET data

被引:574
作者
Defrise, M
Kinahan, PE
Townsend, DW
Michel, C
Sibomana, M
Newport, DF
机构
[1] NATL FUND SCI RES, LOUVAIN, BELGIUM
[2] UNIV PITTSBURGH, MED CTR, PET FACIL, PITTSBURGH, PA 15260 USA
[3] UNIV CATHOLIQUE LOUVAIN, PET LAB, B-1348 LOUVAIN, BELGIUM
[4] CTI, KNOXVILLE, TN 37921 USA
关键词
image reconstruction; medical imaging; positron emission tomography; X-ray transform;
D O I
10.1109/42.563660
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper presents two new rebinning algorithms for the reconstruction of three-dimensional (3-D) positron emission tomography (PET) data, A rebinning algorithm is one that first sorts the 3-D data into an ordinary two-dimensional (2-D) data set containing one sinogram for each transaxial slice to be reconstructed; the 3-D image is then recovered by applying to each slice a 2-D reconstruction method such as filtered-backprojection, This approach allows a significant speedup of 3-D reconstruction, which is particularly useful for applications involving dynamic acquisitions or whole-body imaging, The first new algorithm is obtained by discretizing an exact analytical inversion formula, The second algorithm, called the Fourier rebinning algorithm (FORE), is approximate but allows an efficient implementation based on taking 2-D Fourier transforms of the data, This second algorithm was implemented and applied to data acquired with the new generation of PET systems and also to simulated data for a scanner with an 18 degrees axial aperture, The reconstructed images were compared to those obtained with the 3-D reprojection algorithm (3DRP) which is the standard ''exact'' 3-D filtered-backprojection method, Results demonstrate that FORE provides a reliable alternative to 3DRP, while at the same time achieving an order of magnitude reduction in processing time.
引用
收藏
页码:145 / 158
页数:14
相关论文
共 43 条
[11]  
DEFRISE M, 1995, P 1995 INT S 3 D REC
[12]  
DEFRISE M, 1992, IEEE 1991 NUCL SCI S, P1919
[13]  
Edholm P. R., 1986, Proceedings of the SPIE - The International Society for Optical Engineering, V671, P8, DOI 10.1117/12.966672
[14]  
EGGER M, 1996, THESIS U LAUSANNE SW
[15]   3D RECONSTRUCTION FOR A MULTIRING PET SCANNER BY SINGLE-SLICE REBINNING AND AXIAL DECONVOLUTION [J].
ERLANDSSON, K ;
ESSER, PD ;
STRAND, SE ;
VANHEERTUM, RL .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :619-629
[16]   NONITERATIVE COMPENSATION FOR THE DISTANCE-DEPENDENT DETECTOR RESPONSE AND PHOTON ATTENUATION IN SPECT IMAGING [J].
GLICK, SJ ;
PENNEY, BC ;
KING, MA ;
BYRNE, CL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (02) :363-374
[17]   CONSISTENT PROJECTION RECONSTRUCTION (CPR) TECHNIQUES FOR MRI [J].
GLOVER, GH ;
NOLL, DC .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (03) :345-351
[18]  
HERMAN GT, 1985, POSITRON EMISSION TO
[19]   ACCELERATED IMAGE-RECONSTRUCTION USING ORDERED SUBSETS OF PROJECTION DATA [J].
HUDSON, HM ;
LARKIN, RS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) :601-609
[20]   CONSTRAINED FOURIER SPACE METHOD FOR COMPENSATION OF MISSING DATA IN EMISSION COMPUTED-TOMOGRAPHY [J].
KARP, JS ;
MUEHLLEHNER, G ;
LEWITT, RM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (01) :21-25