Chemometric study and optimization of extraction parameters in single-drop microextraction for the determination of multiclass pesticide residues in grapes and apples by gas chromatography mass spectrometry

被引:50
作者
Amvrazi, Elpiniki G. [1 ]
Tsiropoulos, Nikolaos G. [1 ]
机构
[1] Univ Thessaly, Dept Agr Crop Prod & Rural Environm, Nea Ionia Volos 38446, Greece
基金
中国国家自然科学基金;
关键词
Single-drop microextraction; Experimental design; Liquid phase extraction; Fruits; Residue analysis; Food analysis; Sample preparation; LIQUID-PHASE MICROEXTRACTION; ELECTRON-CAPTURE DETECTION; ORGANOPHOSPHORUS PESTICIDES; ORGANOCHLORINE PESTICIDES; NITROGEN-PHOSPHORUS; SOLVENT-EXTRACTION; NATURAL-WATER; SAMPLES; VEGETABLES; MICRODROP;
D O I
10.1016/j.chroma.2009.08.092
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
A simple and rapid single-drop microextraction method coupled with gas chromatography and mass spectrometry (SDME-GC/MS) for the determination of 20 pesticides with different physicochemical properties in grapes and apples was optimized by the use of a multivariate strategy. Emphasis on the optimization study was given to the role of ionic strength, sugar concentration and pH of the donor sample solution prepared from the fruit samples. Since all three variables were found to affect negatively SDME (a lower extraction efficiency was observed as the values of variables were increased for most of the pesticides studied), donor sample solution was optimized using a central composite design to evaluate the optimum pH value and the optimum dilution of the sample extract. With some exceptions (chlorpyrifos ethyl, alpha-endosulfan, beta-endosulfan, pyriproxyfen, gamma-cyhalothrin and bifenthrin), the optimum method included the dilution of the analytical sample by 12.5-fold with a buffered acetone/water solution at pH = 4 and exhibited good analytical characteristics for the majority of target analytes (pyrimethanil, pirimicarb, metribuzin, vinclozolin, fosthiazate, procymidone, fludioxonil, kresoxim methyl, endosulfan sulfate, fenhexamid, iprodione, phosalone, indoxacarb and azoxystrobin) by providing high enrichment factors (14-328), low limits of detection (0.0003-0.007 mu g/g), and good precision (relative standard deviations below 15%). (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:7630 / 7638
页数:9
相关论文
共 28 条
[1]
Determination of organophosphorus pesticides in water samples by single drop microextraction and gas chromatography-flame photometric detector [J].
Ahmadi, F ;
Assadi, Y ;
Hosseini, SMRM ;
Rezaee, M .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1101 (1-2) :307-312
[2]
Application of single-drop microextraction coupled with gas chromatography for the determination of multiclass pesticides in vegetables with nitrogen phosphorus and electron capture detection [J].
Amvrazi, E. G. ;
Tsiropoulos, N. G. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (14) :2789-2797
[3]
Pesticide enrichment factors and matrix effects on the determination of multiclass pesticides in tomato samples by single-drop microextraction (SDME) coupled with gas chromatography and comparison study between SDME and acetone-partition extraction procedure [J].
Amvrazi, Elpiniki G. ;
Papadi-Psyllou, Asimina T. ;
Tsiropoulos, Nikolaos G. .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2010, 90 (3-6) :245-259
[4]
Evaluation of analyte protectants to improve gas chromatographic analysis of pesticides [J].
Anastassiades, M ;
Mastovská, K ;
Lehotay, SJ .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1015 (1-2) :163-184
[5]
Hybrid single-nanowire photonic crystal and microresonator structures [J].
Barrelet, CJ ;
Bao, JM ;
Loncar, M ;
Park, HG ;
Capasso, F ;
Lieber, CM .
NANO LETTERS, 2006, 6 (01) :11-15
[6]
Single-drop liquid-phase microextraction for the determination of hypericin, pseudohypericin and hyperforin in biological fluids by high performance liquid chromatography [J].
Gioti, EM ;
Skalkos, DC ;
Fiamegos, YC ;
Stalikas, CD .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1093 (1-2) :1-10
[7]
Liquid phase microextraction in a single drop of organic solvent by using a conventional microsyringe [J].
He, Y ;
Lee, HK .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4634-4640
[8]
Determination of pesticides in soil by liquid-phase microextraction and gas chromatography-mass spectrometry [J].
Hou, L ;
Lee, HK .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1038 (1-2) :37-42
[9]
Automated hollow fiber-protected dynamic liquid-phase microextraction of pesticides for gas chromatography - Mass spectrometric analysis [J].
Hou, L ;
Shen, G ;
Lee, HK .
JOURNAL OF CHROMATOGRAPHY A, 2003, 985 (1-2) :107-116
[10]
Mass transfer characteristics of solvent extraction into a single drop at the tip of a syringe needle [J].
Jeannot, MA ;
Cantwell, FF .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :235-239