Determination of erythromycin and related substances in commercial samples using liquid chromatography/ion trap mass spectrometry

被引:30
作者
Deubel, A.
Fandino, A. S.
Soergel, F.
Holzgrabe, U.
机构
[1] Univ Wurzburg, Inst Pharm & Food Chem, D-97074 Wurzburg, Germany
[2] Inst Biomed & Pharmaceut Res, D-90562 Nurnberg, Germany
[3] Univ Duisburg Gesamthsch, Sch Med, Dept Pharmacol, D-45122 Essen, Germany
关键词
erythromycin; related substances; LC/MS/MS;
D O I
10.1016/j.chroma.2006.09.057
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive, precise and accurate quantitative liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the measurement of erythromycin A (EA) and related substances in commercial samples was developed and validated. The samples were chromatographed on a reversed-phase column with a polar endcapping and analyzed by ion trap tandem mass spectrometry in the multiple reaction monitoring (MRM) mode using positive electrospray ionization. The method showed high recovery (>= 98.82%), high sensitivity (lower limit of quantitation of 0.25 ng/mL for EA and less than 7.3 ng/mL for the related substances) and high precision (<= 0.52%) as well as excellent linearity (r(2) > 0.991) with a run time of only 13 min. The method was successfully applied to the determination of EA and related substances in commercial samples. Moreover, using the advanced data-dependent acquisition capability of the ion trap software two new unexpected EA related substances could be detected and possible structures for these substances were postulated. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:39 / 47
页数:9
相关论文
共 42 条
[1]   Analysis of macrolide antibiotics in river water by solid-phase extraction and liquid chromatography-mass spectrometry [J].
Abuin, S ;
Codony, R ;
Compañó, R ;
Granados, M ;
Prat, MD .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1114 (01) :73-81
[2]  
[Anonymous], 2005, European Pharmacopoeia, VVolume 2
[3]  
Bajic S, 2000, RAPID COMMUN MASS SP, V14, P156, DOI 10.1002/(SICI)1097-0231(20000215)14:3&lt
[4]  
156::AID-RCM850&gt
[5]  
3.0.CO
[6]  
2-K
[7]   QUANTITATIVE-ANALYSIS OF ERYTHROMYCIN BY REVERSED-PHASE LIQUID-CHROMATOGRAPHY USING COLUMN-SWITCHING [J].
CACHET, T ;
DETURCK, K ;
ROETS, E ;
HOOGMARTENS, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1991, 9 (07) :547-555
[8]   DECOMPOSITION KINETICS OF ERYTHROMYCIN-A IN ACIDIC AQUEOUS-SOLUTIONS [J].
CACHET, T ;
VANDENMOOTER, G ;
HAUCHECORNE, R ;
VINCKIER, C ;
HOOGMARTENS, J .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1989, 55 (01) :59-65
[9]   Separation of erythromycin and related substances on base-deactivated reversed-phase silica gel columns [J].
Chepkwony, HK ;
Vanderriest, I ;
Nguyo, JM ;
Roets, E ;
Hoogmartens, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 870 (1-2) :227-235
[10]   Identification of impurities in erythromycin by liquid chromatography-mass spectrometric detection [J].
Chitneni, SK ;
Govaerts, C ;
Adams, E ;
Van Schepdael, A ;
Hoogmartens, J .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1056 (1-2) :111-120