Quantitative Susceptibility Map Reconstruction from MR Phase Data Using Bayesian Regularization: Validation and Application to Brain Imaging

被引:556
作者
de Rochefort, Ludovic [1 ,2 ]
Liu, Tian [1 ]
Kressler, Bryan [1 ]
Liu, Jing [1 ]
Spincemaille, Pascal [1 ]
Lebon, Vincent [2 ]
Wu, Jianlin [3 ]
Wang, Yi [1 ]
机构
[1] Cornell Univ, Cornell Cardiovasc Magnet Resonance Imaging Lab, Dept Radiol, Weill Med Coll, New York, NY 10021 USA
[2] CEA, MIRCen, LMN, 12BM,DSV, Fontenay Aux Roses, France
[3] Dalian Med Univ, Dept Radiol, Hosp 1, Dalian, Liaoning, Peoples R China
关键词
brain iron; susceptibility quantification; magnetic field; inverse problem; regularization; INDUCED MAGNETIC-FIELD; CONTRAST; INHOMOGENEITY; QUANTIFICATION; SUSCEPTOMETRY;
D O I
10.1002/mrm.22187
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The diagnosis of many neurologic diseases benefits from the ability to quantitatively assess iron in the brain. Paramagnetic iron modifies the magnetic susceptibility causing magnetic field inhomogeneity in MRI. The local field can be mapped using the MR signal phase, which is discarded in a typical image reconstruction. The calculation of the susceptibility from the measured magnetic field is an ill-posed inverse problem. In this work, a bayesian regularization approach that adds spatial priors from the MR magnitude image is formulated for susceptibility imaging. Priors include background regions of known zero susceptibility and edge information from the magnitude image. Simulation and phantom validation experiments demonstrated accurate susceptibility maps free of artifacts. The ability to characterize iron content in brain hemorrhage was demonstrated on patients with cavernous hemangioma. Additionally, multiple structures within the brain can be clearly visualized and characterized. The technique introduces a new quantitative contrast in MRI that is directly linked to iron in the brain. Magn Reson Med 63:194-206, 2010. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:194 / 206
页数:13
相关论文
共 52 条
  • [1] Contrast-agent phase effects: An experimental system for analysis of susceptibility, concentration, and bolus input function kinetics
    Akbudak, E
    Norberg, RE
    Conturo, TE
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) : 990 - 1002
  • [2] SUSCEPTIBILITY CHANGES FOLLOWING BOLUS INJECTIONS
    ALBERT, MS
    HUANG, W
    LEE, JH
    PATLAK, CS
    SPRINGER, CS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (05) : 700 - 708
  • [3] [Anonymous], 1999, CLASSICAL ELECTRODYN
  • [4] Ben-Israel A., 2000, GEN INVERSES THEORY
  • [5] Beutler Ernest, 2003, Hematology Am Soc Hematol Educ Program, P40
  • [6] MRI measurement of hepatic magnetic susceptibility - Phantom validation and normal subject studies
    Chu, ZL
    Cohen, AR
    Muthupillai, R
    Chung, T
    Wang, ZYJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (06) : 1318 - 1327
  • [7] Numerical calculations of the static magnetic field in three-dimensional multi-tissue models of the human head
    Collins, CM
    Yang, B
    Yang, QX
    Smith, MB
    [J]. MAGNETIC RESONANCE IMAGING, 2002, 20 (05) : 413 - 424
  • [8] SIGNAL-TO-NOISE IN PHASE-ANGLE RECONSTRUCTION - DYNAMIC-RANGE EXTENSION USING PHASE REFERENCE OFFSETS
    CONTURO, TE
    SMITH, GD
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (03) : 420 - 437
  • [9] Recent advances in iron oxide nanocrystal technology for medical imaging
    Corot, Claire
    Robert, Philippe
    Idee, Jean-Marc
    Port, Marc
    [J]. ADVANCED DRUG DELIVERY REVIEWS, 2006, 58 (14) : 1471 - 1504
  • [10] Quantitative MR susceptibility mapping using piece-wise constant regularized inversion of the magnetic field
    de Rochefort, Ludovic
    Brown, Ryan
    Prince, Martin R.
    Wang, Yi
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (04) : 1003 - 1009