Miniaturized flow-through PCR with different template types in a silicon chip thermocycler

被引:172
作者
Schneegass, I
Bräutigam, R
Köhler, JM
机构
[1] Inst Phys High Technol, Dept Biotech Micro Syst, Div Micro Syst, D-07745 Jena, Germany
[2] CLONDIAG Chip Technol GmbH, D-07743 Jena, Germany
来源
LAB ON A CHIP | 2001年 / 1卷 / 01期
关键词
D O I
10.1039/b103846j
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Flow-through chip thermocyclers can be used in miniaturized rapid polymerase chain reaction (PCR) despite their high surface to volume ratio of samples. We demonstrated that a thermocycler made of silicon and glass chips and containing thin film transducers for heating and temperature control can be adapted to the amplification of various DNA templates of different sources and properties. Therefore, the concept of serial flow in a liquid/liquid two-phase system was combined with a surface management of inner side walls of the microchannel and an adaptation of PCR mixture composition. In addition, the process temperatures and the flow rates were optimized. Thus, a synthetic template originating from investigations on nucleic acid evolution with 106 base pairs [cooperative amplification of templates by cross hybridization (CATCH)], a house keeping gene with 379 base pairs [glutaraldehyde 3-phosphate dehydrogenase (GAPDH)] and a zinc finger protein relevant in human pathogenesis with 700 base pairs [Myc-interacting zinc finger protein-1, knock-out (Miz1-KO)] were amplified successfully. In all three cases the selectivity of priming and amplification could be shown by gel electrophoresis. The typical amplification time was 1 min per temperature cycle. So, the typical residence time of a sample volume inside the 25 cycle device amounts to less then half an hour. The energy consumption of the PCR chip for a 35 min PCR process amounts to less than 0.012 kW h.
引用
收藏
页码:42 / 49
页数:8
相关论文
共 29 条
  • [1] MEASUREMENT OF GENE-EXPRESSION BY MULTIPLEX COMPETITIVE POLYMERASE CHAIN-REACTION
    APOSTOLAKOS, MJ
    SCHUERMANN, WHT
    FRAMPTON, MW
    UTELL, MJ
    WILLEY, JC
    [J]. ANALYTICAL BIOCHEMISTRY, 1993, 213 (02) : 277 - 284
  • [2] An integrated nanoliter DNA analysis device
    Burns, MA
    Johnson, BN
    Brahmasandra, SN
    Handique, K
    Webster, JR
    Krishnan, M
    Sammarco, TS
    Man, PM
    Jones, D
    Heldsinger, D
    Mastrangelo, CH
    Burke, DT
    [J]. SCIENCE, 1998, 282 (5388) : 484 - 487
  • [3] Chip PCR .2. Investigation of different PCR amplification systems in microfabricated silicon-glass chips
    Cheng, J
    Shoffner, MA
    Hvichia, GE
    Kricka, LJ
    Wilding, P
    [J]. NUCLEIC ACIDS RESEARCH, 1996, 24 (02) : 380 - 385
  • [4] Clinical potential of microchip capillary electrophoresis systems
    Colyer, CL
    Tang, T
    Chiem, N
    Harrison, DJ
    [J]. ELECTROPHORESIS, 1997, 18 (10) : 1733 - 1741
  • [5] Silicon microchambers for DNA amplification
    Daniel, JH
    Iqbal, S
    Millington, RB
    Moore, DF
    Lowe, CR
    Leslie, DL
    Lee, MA
    Pearce, MJ
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1998, 71 (1-2) : 81 - 88
  • [6] Cooperative amplification of templates by cross-hybridization (CATCH)
    Ehricht, R
    Ellinger, T
    McCaskill, JS
    [J]. EUROPEAN JOURNAL OF BIOCHEMISTRY, 1997, 243 (1-2): : 358 - 364
  • [7] In vitro evolution of molecular cooperation in CATCH, a cooperatively coupled amplification system
    Ellinger, T
    Ehricht, R
    McCaskill, JS
    [J]. CHEMISTRY & BIOLOGY, 1998, 5 (12): : 729 - 741
  • [8] Freemantle M, 1999, CHEM ENG NEWS, V77, P27, DOI 10.1021/cen-v077n044.p027
  • [9] MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP
    HARRISON, DJ
    FLURI, K
    SEILER, K
    FAN, ZH
    EFFENHAUSER, CS
    MANZ, A
    [J]. SCIENCE, 1993, 261 (5123) : 895 - 897
  • [10] Chemical amplification: Continuous-flow PCR on a chip