Improved ion extraction from a linear octopole ion trap: SIMION analysis and experimental demonstration

被引:140
作者
Wilcox, BE [1 ]
Hendrickson, CL [1 ]
Marshall, AG [1 ]
机构
[1] Florida State Univ, Natl High Magnet Field Lab, Ion Cyclotron Resonance Program, Dept Chem, Tallahassee, FL 32310 USA
基金
美国国家科学基金会;
关键词
D O I
10.1016/S1044-0305(02)00622-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Externally generated ions are accumulated in a linear octopole ion trap before injection into our 9.4 T Fourier transform ion cyclotron resonance (FT-ICR) mass analyzer. Such instrumental configuration has previously been shown to provide improved sensitivity, scan rate, and duty cycle relative to accumulated trapping in the ICR cell. However, inefficient ion ejection from the octopole currently limits both detection limit and scan rate. SIMION 7.0 analysis predicts that a dc axial electric field inside the linear octopole ion trap expedites and synchronizes the efficient extraction of the octopole-accumulated ions. Further SIMION analysis optimizes the ion ejection properties of each of three electrode configurations designed to produce a near-linear axial potential gradient. More efficient extraction and transfer of accumulated ions spanning a wide m/z range promises to reduce detection limit and increase front-end sampling rate (e.g., to increase front-end resolution for separation techniques coupled with FT-ICR mass analysis). Addition of the axial field improves experimental signal-to-noise ratio by more than an order of magnitude. (C) 2002 American Society for Mass Spectrometry.
引用
收藏
页码:1304 / 1312
页数:9
相关论文
共 42 条
[1]   METAL CLUSTER ION-CYCLOTRON RESONANCE - COMBINING SUPERSONIC METAL CLUSTER BEAM TECHNOLOGY WITH FT-ICR [J].
ALFORD, JM ;
WILLIAMS, PE ;
TREVOR, DJ ;
SMALLEY, RE .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1986, 72 (1-2) :33-51
[2]   Design and performance of an ESI interface for selective external ion accumulation coupled to a Fourier transform ion cyclotron mass spectrometer [J].
Belov, ME ;
Nikolaev, EN ;
Anderson, GA ;
Udseth, HR ;
Conrads, TP ;
Veenstra, TD ;
Masselon, CD ;
Gorshkov, MV ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2001, 73 (02) :253-261
[3]   DEBYE-SHIELDING MECHANISM FOR TRAPPING IONS FORMED BY LASER DESORPTION FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BEU, SC ;
HENDRICKSON, CL ;
VARTANIAN, VH ;
LAUDE, DA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 113 (01) :59-79
[4]  
Bier M. E., 1995, U. S. Patent, Patent No. [5,420,425 A, 5420425]
[5]  
BLAKNEY GT, 2001, P 49 ASMS C MASS SPE
[6]  
DAVIDSON RC, 1990, PHYSICS NONNEUTRAL P
[7]  
Dawson PH., 1995, QUADRUPOLE MASS SPEC, DOI 10.1016/
[8]  
Dodonov A, 1997, RAPID COMMUN MASS SP, V11, P1649, DOI 10.1002/(SICI)1097-0231(19971015)11:15<1649::AID-RCM67>3.0.CO
[9]  
2-T
[10]   Application of micro-electrospray liquid chromatography techniques to FT-ICR MS to enable high-sensitivity biological analysis [J].
Emmett, MR ;
White, FM ;
Hendrickson, CL ;
Shi, SDH ;
Marshall, AG .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (04) :333-340