Improved perfusion-weighted MRI by a novel double inversion with proximal labeling of both tagged and control acquisitions

被引:34
作者
Jahng, GH [1 ]
Zhu, XP [1 ]
Matson, GB [1 ]
Weiner, MW [1 ]
Schuff, N [1 ]
机构
[1] Univ Calif San Francisco, VA Med Ctr, MR Unit, San Francisco, CA 94121 USA
关键词
PASL; double inversion; MT compensation; texture analyses; cerebral blood flow;
D O I
10.1002/mrm.10339
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A novel pulsed arterial spin labeling (PASL) technique for multislice perfusion-weighted imaging is proposed that compensates for magnetization transfer (MT) effects without sacrificing tag efficiency, and balances transient magnetic field effects (eddy currents) induced by pulsed field gradients. Improved compensation for MT is demonstrated using a phantom. Improvement in perfusion measurement was compared to other PASL techniques by acquiring perfusion images from 13 healthy volunteers (nine women and four men; age range 29-64 years; mean age 45 +/- 14 years) and second-order image texture analysis. The main improvements with the new method were significantly higher image contrast, higher mean signal intensity, and better signal uniformity across slices. In conclusion, this new PASL method should provide improved accuracy in measuring brain perfusion. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:307 / 314
页数:8
相关论文
共 37 条
[1]  
Alsop DC, 2000, ANN NEUROL, V47, P93, DOI 10.1002/1531-8249(200001)47:1<93::AID-ANA15>3.0.CO
[2]  
2-8
[3]   RELAXATION RATES OF PARAMAGNETIC SOLUTIONS - EVALUATION BY NUCLEAR-MAGNETIC-RESONANCE IMAGING [J].
BUCCIOLINI, M ;
CIRAOLO, L ;
RENZI, R .
MEDICAL PHYSICS, 1986, 13 (03) :298-303
[4]   Noninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease [J].
Detre, JA ;
Alsop, DC ;
Vives, LR ;
Maccotta, L ;
Teener, JW ;
Raps, EC .
NEUROLOGY, 1998, 50 (03) :633-641
[5]   High-sensitivity single-shot perfusion-weighted fMRI [J].
Duyn, JH ;
Tan, CX ;
van Gelderen, P ;
Yongbi, MN .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :88-94
[6]   QUALITATIVE MAPPING OF CEREBRAL BLOOD-FLOW AND FUNCTIONAL LOCALIZATION WITH ECHO-PLANAR MR-IMAGING AND SIGNAL TARGETING WITH ALTERNATING RADIO-FREQUENCY [J].
EDELMAN, RR ;
SIEWERT, B ;
DARBY, DG ;
THANGARAJ, V ;
NOBRE, AC ;
MESULAM, MM ;
WARACH, S .
RADIOLOGY, 1994, 192 (02) :513-520
[7]   EPISTAR MRI: Multislice mapping of cerebral blood flow [J].
Edelman, RR ;
Chen, G .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) :800-805
[8]   Slice profile effects in adiabatic inversion: Application to multislice perfusion imaging [J].
Frank, LR ;
Wong, EC ;
Buxton, RB .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) :558-564
[9]  
Golay X, 1999, JMRI-J MAGN RESON IM, V9, P454, DOI 10.1002/(SICI)1522-2586(199903)9:3<454::AID-JMRI14>3.3.CO
[10]  
2-2