Improved perfusion-weighted MRI by a novel double inversion with proximal labeling of both tagged and control acquisitions

被引:34
作者
Jahng, GH [1 ]
Zhu, XP [1 ]
Matson, GB [1 ]
Weiner, MW [1 ]
Schuff, N [1 ]
机构
[1] Univ Calif San Francisco, VA Med Ctr, MR Unit, San Francisco, CA 94121 USA
关键词
PASL; double inversion; MT compensation; texture analyses; cerebral blood flow;
D O I
10.1002/mrm.10339
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A novel pulsed arterial spin labeling (PASL) technique for multislice perfusion-weighted imaging is proposed that compensates for magnetization transfer (MT) effects without sacrificing tag efficiency, and balances transient magnetic field effects (eddy currents) induced by pulsed field gradients. Improved compensation for MT is demonstrated using a phantom. Improvement in perfusion measurement was compared to other PASL techniques by acquiring perfusion images from 13 healthy volunteers (nine women and four men; age range 29-64 years; mean age 45 +/- 14 years) and second-order image texture analysis. The main improvements with the new method were significantly higher image contrast, higher mean signal intensity, and better signal uniformity across slices. In conclusion, this new PASL method should provide improved accuracy in measuring brain perfusion. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:307 / 314
页数:8
相关论文
共 37 条
[11]   TEXTURAL FEATURES FOR IMAGE CLASSIFICATION [J].
HARALICK, RM ;
SHANMUGAM, K ;
DINSTEIN, I .
IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1973, SMC3 (06) :610-621
[12]   Clinical studies of cerebral blood flow in Alzheimer's disease [J].
Jagust, WJ ;
Eberling, JL ;
Reed, BR ;
Mathis, CA ;
Budinger, TF .
CEREBROVASCULAR PATHOLOGY IN ALZHEIMER'S DISEASE, 1997, 826 :254-262
[13]   CORRECTION FOR GEOMETRIC DISTORTION IN ECHO-PLANAR IMAGES FROM B-0 FIELD VARIATIONS [J].
JEZZARD, P ;
BALABAN, RS .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) :65-73
[14]   Theoretical analysis of the effect of imperfect slice profiles on tagging schemes for pulsed arterial spin labeling MRI [J].
Keilholz-George, SD ;
Knight-Scott, J ;
Berr, SS .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :141-148
[15]   QUANTIFICATION OF RELATIVE CEREBRAL BLOOD-FLOW CHANGE BY FLOW-SENSITIVE ALTERNATING INVERSION-RECOVERY (FAIR) TECHNIQUE - APPLICATION TO FUNCTIONAL MAPPING [J].
KIM, SG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :293-301
[16]   MR PERFUSION STUDIES WITH T-1-WEIGHTED ECHO-PLANAR IMAGING [J].
KWONG, KK ;
CHESLER, DA ;
WEISSKOFF, RM ;
DONAHUE, KM ;
DAVIS, TL ;
OSTERGAARD, L ;
CAMPBELL, TA ;
ROSEN, BR .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) :878-887
[17]   FAIR exempting separate T1 measurement (FAIREST):: a novel technique for online quantitative perfusion imaging and multi-contrast fMRI [J].
Lai, S ;
Wang, JJ ;
Jahng, GH .
NMR IN BIOMEDICINE, 2001, 14 (7-8) :507-516
[18]  
Lei H, 1999, MAGN RESON MED, V41, P563, DOI 10.1002/(SICI)1522-2594(199903)41:3<563::AID-MRM20>3.0.CO
[19]  
2-6
[20]  
Luh WM, 1999, MAGNET RESON MED, V41, P1246, DOI 10.1002/(SICI)1522-2594(199906)41:6<1246::AID-MRM22>3.0.CO