Normal values for renal length and volume as measured by magnetic resonance imaging

被引:195
作者
Cheong, Benjamin
Muthupillai, Raja
Rubin, Mario F.
Flamm, Scott D.
机构
[1] St Lukes Episcopal Hosp, Texas Heart Inst, Dept Radiol, Houston, TX USA
[2] St Lukes Episcopal Hosp, Texas Heart Inst, Dept Cardiol, Houston, TX USA
[3] St Lukes Episcopal Hosp, Texas Heart Inst, Dept Nephrol, Houston, TX USA
[4] Philips Med Syst, Cleveland, OH USA
[5] Baylor Coll Med, Dept Med, Houston, TX 77030 USA
[6] Baylor Coll Med, Dept Radiol, Houston, TX 77030 USA
来源
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY | 2007年 / 2卷 / 01期
关键词
D O I
10.2215/CJN.00930306
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The objective of this magnetic resonance imaging (MRI) study was to (1) test the validity of the ellipsoid formula for estimating kidney volume using ex vivo and in vivo models and (2) establish a normal range of values for kidney length and volume in patients with no known history of renal disease. The volumes of five excised porcine kidneys were measured by (1) disc-summation method, (2) ellipsoid formula, and (3) water displacement method. In a retrospective, consecutive group of clinically referred patients (n=150; 300 kidneys), individual kidney volume and length were calculated by the disc-summation method and by multiplanar reformation of MRI data, respectively. For comparison, kidney volumes also were calculated using the ellipsoid formula in all patients. Renal volume that was obtained by MRI using the disc-summation method was within 5% of the volume that was determined by the water displacement method, independent of the spatial resolution of the MRI technique used. Data from both the in vivo and the ex vivo models revealed that the ellipsoid formula that commonly is used in ultrasonography underestimates renal volume by 17 to 29% compared with the disc-summation method (P<0.05). As measured by MRI (mean +/- SD), kidney lengths were 12.4 +/- 0.9 cm for men and 11.6 +/- 1.1 cm for women, and kidney volumes were 202 +/- 36 ml for men and 154 +/- 33 ml for women. The results from the ex vivo MRI study show that the kidney volume that was obtained using the disc-summation method is within 5% of the true kidney volume as measured by the water displacement method. The ellipsoid formula consistently and significantly underestimates the true kidney volume. The length and the volume of kidneys that are obtained by MRI in patients with no known history of intrinsic renal disease are greater than the commonly quoted reference values that are obtained by ultrasonography.
引用
收藏
页码:38 / 45
页数:8
相关论文
共 24 条
[1]  
ALLAN P, 2001, CLIN ULTRASOUND COMP, P513
[2]   In vitro measurement of kidney size: Comparison of ultrasonography and MRI [J].
Bakker, J ;
Olree, M ;
Kaatee, R ;
de Lange, EE ;
Beek, FJA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (05) :683-688
[3]   Renal volume measurements: Accuracy and repeatability of US compared with that of MR imaging [J].
Bakker, J ;
Olree, M ;
Kaatee, R ;
de Lange, EE ;
Moons, KGM ;
Beutler, JJ ;
Beek, FJA .
RADIOLOGY, 1999, 211 (03) :623-628
[4]   Characterization of renal artery stenoses based on magnetic resonance renal flow and volume measurements [J].
Binkert, CA ;
Hoffman, U ;
Leung, DA ;
Matter, HG ;
Schmidt, M ;
Debatin, JF .
KIDNEY INTERNATIONAL, 1999, 56 (05) :1846-1854
[5]   Can MR measurement of renal artery flow and renal volume predict the outcome of percutaneous transluminal renal angioplasty? [J].
Binkert, CA ;
Debatin, JF ;
Schneider, E ;
Hodler, J ;
Ruehm, SG ;
Schmidt, M ;
Hoffmann, U .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 24 (04) :233-239
[6]   ULTRASOUND ASSESSMENT OF NORMAL RENAL DIMENSIONS [J].
BRANDT, TD ;
NEIMAN, HL ;
DRAGOWSKI, MJ ;
BULAWA, W ;
CLAYKAMP, G .
JOURNAL OF ULTRASOUND IN MEDICINE, 1982, 1 (02) :49-52
[7]  
BRENNER BM, 1992, J AM SOC NEPHROL, V3, P162
[8]  
Cochlin DL, 1998, DIAGNOSTIC ULTRASOUN, P788
[9]   Measurement of renal volumes with contrast-enhanced MRI [J].
Coulam, CH ;
Bouley, DM ;
Sommer, FG .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (02) :174-179
[10]   ACCURACY OF VOLUME MEASUREMENTS OF COMPUTED-TOMOGRAPHY AND MAGNETIC-RESONANCE-IMAGING PHANTOMS BY 3-DIMENSIONAL RECONSTRUCTION AND PRELIMINARY CLINICAL-APPLICATION [J].
DISLER, DG ;
MARR, DS ;
ROSENTHAL, DI .
INVESTIGATIVE RADIOLOGY, 1994, 29 (08) :739-745