Laboratory calibration of the Extreme-Ultraviolet Imaging Spectrometer for the Solar-B satellite

被引:101
作者
Lang, James [1 ]
Kent, Barry J.
Paustian, Wolfgang
Brown, Charles M.
Keyser, Christian
Anderson, Mark R.
Case, Giles C. R.
Chaudry, Rahil A.
James, Adrian M.
Korendyke, Clarence M.
Pike, C. David
Probyn, Brian J.
Rippington, David J.
Seely, John F.
Tandy, Jason A.
Whillock, Matthew C. R.
机构
[1] Rutherford Appleton Lab, Didcot OX11 0QX, Oxon, England
[2] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
[3] USN, Res Lab, Div Space Sci, Washington, DC 20375 USA
[4] UCL, Mullard Space Sci Lab, Dorking RH5 6NT, Surrey, England
[5] Univ Birmingham, Sch Phys & Space Res, Birmingham B15 2TT, W Midlands, England
关键词
D O I
10.1364/AO.45.008689
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The laboratory end-to-end testing of the Extreme-Ultraviolet Imaging Spectrometer (EIS) for the Solar-B satellite is reported. A short overview of the EIS, which observes in two bands in the extreme-ultraviolet wavelength range, is given. The calibration apparatus is described, including details of the light sources used. The data reduction and analysis procedure are outlined. The wavelength calibration using a Penning source to illuminate the aperture fully is presented. We discuss the aperture determination using a radiometrically calibrated hollow-cathode-based source. We then give an account of the predicted and measured efficiencies from consideration of the efficiencies of individual optical elements in first order, an account of efficiencies out of band when radiation incident in one band is detected in the other, and efficiencies in multiple orders. The efficiencies measured in first order for in band and out of band are compared with the predictions and the sensitivity, and its uncertainties are derived. Application of the radiometric calibration is discussed. (c) 2006 Optical Society of America.
引用
收藏
页码:8689 / 8705
页数:17
相关论文
共 35 条
[21]   The laboratory calibration of the SOHO Coronal Diagnostic Spectrometer [J].
Lang, J ;
Kent, BJ ;
Breeveld, AA ;
Breeveld, ER ;
Bromage, BJI ;
Hollandt, J ;
Payne, J ;
Pike, CD ;
Thompson, WT .
JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2000, 2 (02) :88-106
[22]  
LANG J, INFLIGHT MONITORING
[23]  
NEWMARK J, 2005, COMMUNICATION
[24]  
POWELL F, 2003, COMMUNICATION SMALL
[25]   CALIBRATION CHANGES IN EUV SOLAR SATELLITE INSTRUMENTS [J].
REEVES, EM ;
PARKINSON, WH .
APPLIED OPTICS, 1970, 9 (05) :1201-+
[26]   PHOTOMETRIC CALIBRATION OF EUV SPECTRO-HELIOMETER ON ATM [J].
REEVES, EM ;
TIMOTHY, JG ;
HUBER, MCE ;
WITHBROE, GL .
APPLIED OPTICS, 1977, 16 (04) :849-857
[27]  
RICHTER M, 2005, RECALIBRATION SUMER
[28]  
Samson J. A., 1967, TECHNIQUES VACUUM UL
[29]   Determination of the electron-hole pair creation energy for semiconductors from the spectral responsivity of photodiodes [J].
Scholze, F ;
Henneken, H ;
Kuschnerus, P ;
Rabus, H ;
Richter, M ;
Ulm, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 439 (2-3) :208-215
[30]   Normal-incidence efficiencies of multi layer-coated laminar gratings for the Extreme-Ultraviolet Imaging Spectrometer on the Solar-B mission [J].
Seely, JF ;
Brown, CM ;
Windt, DL ;
Donguy, S ;
Kjornrattanawanich, B .
APPLIED OPTICS, 2004, 43 (07) :1463-1471