Adaptive modification of treatment planning to minimize the deleterious effects of treatment setup errors

被引:183
作者
Yan, D [1 ]
Wong, J [1 ]
Vicini, F [1 ]
Michalski, J [1 ]
Pan, C [1 ]
Frazier, A [1 ]
Horwitz, E [1 ]
Martinez, A [1 ]
机构
[1] WASHINGTON UNIV,SCH MED,MALLINCKRODT INST RADIOL,ST LOUIS,MO
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1997年 / 38卷 / 01期
关键词
adaptive radiation therapy; treatment setup error; conformal therapy and dose escalation;
D O I
10.1016/S0360-3016(97)00229-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Using daily setup variation measured from an electronic portal imaging device (EPID), radiation treatment of the individual patient can be adaptively reoptimized during the course of therapy. In this study, daily portal images were retrospectively examined to: (a) determine the number of initial days of portal imaging required to give adequate prediction of the systematic and random setup errors; and (b) explore the potential of using the prediction as feedback to reoptimize the individual treatment part-way through the treatment course. Methods and Materials: Daily portal images of 64 cancer patients, whose treatment position was not adjusted during the course of treatment, were obtained from two independent clinics with similar setup procedures. Systematic and random setup errors for each patient were predicted using different numbers of initial portal measurements. The statistical confidence of the predictions was tested to determine the number of daily portal measurements needed to give reasonable predictions. Two treatment processes, were simulated to examine the potential opportunity for setup margin reduction and dose escalation. The first process mimicked a conventional treatment. A constant margin was assigned to each treatment field to compensate for the average setup error of the patient population. A treatment dose was then prescribed, with reference to a fixed normal tissue tolerance, and then fixed in the entire course of treatment. In the second process, the same treatment fields and prescribed dose were used only for the initial plan and treatment. After several initial days of treatments, the treatment field shape and position were assumed to be adaptively modified using a computer-controlled multileaf collimator (MLC) in light of the predicted systematic and random setup errors, The prescribed dose was then escalated until the same normal tissue tolerance, as determined in the first treatment process, was reached. Results: The systematic setup error and the random setup error were predicted to be within +/-1 mm for the former and +/-0.5 mm for the latter at a greater than or equal to 95% confidence level using less than or equal to 9 initial daily portal measurements. In the study, a large number of patients could be treated using a smaller held margin if the adaptive modification process were used. Simulation of the adaptive modification process for prostate treatment demonstrates that additional treatment dose could be safely applied to 64% of patients. Conclusion: The adaptive modification process represents a different approach for use of on-line portal images. The portal imaging information from the initial treatments is used as feedback for reoptimization of the treatment plan, rather than adjustment of the treatment setup. Results from the retrospective study show that the treatment of individual patient can be improved with the adaptive modification process. (C) 1997 Elsevier Science Inc.
引用
收藏
页码:197 / 206
页数:10
相关论文
共 23 条
[1]  
*3D CRT ONC GROUP, 1995, 9406 3DOG 3DCRT ONC
[2]  
Anderson B. D. O., 1979, OPTIMAL FILTERING
[3]  
[Anonymous], 1993, 50 ICRU
[4]   A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES [J].
BEL, A ;
VANHERK, M ;
BARTELINK, H ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :253-260
[5]   OBJECTIVE DECISION-MAKING FOLLOWING A PORTAL FILM - THE RESULTS OF A PILOT-STUDY [J].
DENHAM, JW ;
DALLY, MJ ;
HUNTER, K ;
WHEAT, J ;
FAHEY, PP ;
HAMILTON, CS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (05) :869-876
[6]   QUALITY-CONTROL AT THE PATIENT LEVEL - ACTION OR RETROSPECTIVE INTROSPECTION [J].
DUTREIX, A ;
VANDERSCHUEREN, E ;
LEUNENS, L .
RADIOTHERAPY AND ONCOLOGY, 1992, 25 (02) :146-147
[7]   CALCULATION OF THE UNCERTAINTY IN THE DOSE DELIVERED DURING RADIATION-THERAPY [J].
GOITEIN, M .
MEDICAL PHYSICS, 1985, 12 (05) :608-612
[8]   AN EVALUATION OF SETUP UNCERTAINTIES FOR PATIENTS TREATED TO PELVIC SITES [J].
HUNT, MA ;
SCHULTHEISS, TE ;
DESOBRY, GE ;
HAKKI, M ;
HANKS, GE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 32 (01) :227-233
[9]  
Kutcher, 1995, Semin Radiat Oncol, V5, P134, DOI 10.1016/S1053-4296(95)80006-9
[10]   CALCULATION OF COMPLICATION PROBABILITY FACTORS FOR NON-UNIFORM NORMAL TISSUE IRRADIATION - THE EFFECTIVE VOLUME METHOD [J].
KUTCHER, GJ ;
BURMAN, C .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 16 (06) :1623-1630